MITSUBISHI
Home >> Products
MITSUBISHI
The PC card interface unit connecting cable
A85GT-C05H


Cable length: 0.5 meters. For the GOT and the PC card interface unit (A1SD59J-MIF) connection. For F
MITSUBISHI
CRT connection cable
AC300VG


Cable length: 30 meters. For connection between GOT and CRT.
MITSUBISHI
cpu module
L02SCPU-P


"Universal output function: source type. Program capacity: 20K step. Basic operations processing spe
MITSUBISHI
cpu module
L02CPU-P


"Universal output function: source type. Program capacity: 20K step. Basic operations processing spe
MITSUBISHI
cpu module
L06CPU-P


"Universal output function: source type. Program capacity: 60K step. Basic operations processing spe
MITSUBISHI
cpu module
L26CPU-CM


"Universal output function: leakage type. Program capacity: 260K step. Basic operations processing s
MITSUBISHI
cpu module
L26CPU-P


"Universal output function: source type. Program capacity: 260K step. Basic operations processing sp
MITSUBISHI
cpu module
L26CPU-BT-CM


"Universal output function: leakage type. Program capacity: 260K step. Basic operations processing s
MITSUBISHI
End cap with ERR terminal
L6EC-ET-CM


Error output. Rated open and close voltage, current: DC24V, 0.5A. Minimum open and close load: DC5V,
MITSUBISHI
Display module
L6DSPU-C-CM


Display characters: 16 x 4 character line width. Display character: English letters and numbers (ful
MITSUBISHI
Extension cable
LC10E-CM


Cable length: 1.0m. Weight: 0.23kg. Definition 1: conductor by one or a plurality of mutually insula
MITSUBISHI
Power module
L63P-CM


Input power: DC24V. Output: DC5V, 5A. Power supply module can be directly pasted on the printed circ
MITSUBISHI
Power module
L63SP


Slim type non isolated. Input power: DC24V. Output: DC5V, 5A. Power supply module can be directly pa
MITSUBISHI
AC input module
LX28-CM


Input points: 8 points. Rated input voltage: AC100 ~ 120V. Common way: 8 point / public end. Input /
MITSUBISHI
DC input module
LX41C4-CM


Input points: 32 points. Rated input voltage: DC24V. Common way: 32 point / public end. Input / outp
MITSUBISHI
DC input module
LX42C4-CM


Enter points: 64 points. Rated input voltage: DC24V. Common way: 32 point / public end. Input / outp
MITSUBISHI
Contact output module
LY10R2-CM


Output points: 16 points. Rated output voltage: DC24V/AC240V. Rated open and close current: 2A/1 poi
MITSUBISHI
Bidirectional thyristor output module
LY20S6-CM


Output points: 16 points. Output form: bidirectional thyristor output. Rated output voltage: AC100 ~
MITSUBISHI
Bidirectional thyristor output module
LY28S1A-CM


Output points: 8 points. Output form: no public side (all points independent). Rated output voltage:
MITSUBISHI
Transistor output module (drain type)
LY40NT5P-CM


Output points: 16 points. Output type: leakage type. Rated output voltage: DC12 ~ 24V. Max load curr
MITSUBISHI
Transistor output module (drain type)
LY42NT1P-CM


Output points: 64 points. Output type: leakage type. Rated output voltage: DC12 ~ 24V. Max load curr
MITSUBISHI
Transistor output module (source)
LY41PT1P-CM


Output points: 32 points. Output form: source type. Rated output voltage: DC12 ~ 24V. Max load curre
MITSUBISHI
Input / output mixed module
LH42C4NT1P-CM


Input points: 32 points. Input voltage: DC24V. Enter the public side of the way: 32 points / public.
MITSUBISHI
Multiple input (voltage / current / temperature) module
L60MD4-G-CM


Number of input channels: 4ch. Input voltage: DC - 10 - 10V. Input current: DC0 ~ 20mA. Input voltag
MITSUBISHI
Analog input module
L60ADVL8-CM


Number of input channels: 8ch. Input voltage: DC - 10 ~ 10V. Conversion speed: 1ms/ch. Resolution: 1
MITSUBISHI
Analog input module
L60ADIL8-CM


Number of input channels: 8ch. Input current: DC0 ~ 20mA. Conversion speed: 1ms/ch. Resolution: 1/80
MITSUBISHI
2 channel analog input module
L60AD4-2GH-CM


Number of input channels: 4ch. Input voltage: DC - 10 ~ 10V. Input current: DC0 ~ 20mA. Conversion s
MITSUBISHI
Analog output module
L60DA4-CM


Output channel number: 4ch. Output voltage: DC - 10 ~ 10V. Output current: DC0 ~ 20mA. Conversion sp
MITSUBISHI
Analog input / output module
L60AD2DA2-CM


Number of input channels: 2Ch. Input voltage: DC - 10 ~ 10V. Input current: DC0 ~ 20mA. Conversion s
MITSUBISHI
Temperature input module
L60RD8-CM


Number of input channels: 8ch. Input temperature resistance: Pt1000, Pt100, JPt100, Pt50, Ni500, Ni1
MITSUBISHI
Temperature control module
L60TCTT4BW-CM


Thermocouple input. Number of input channels: 4ch. Detection function of broken wire with heater. St
MITSUBISHI
Temperature control module
L60TCRT4-CM


Temperature measurement resistor input. Number of input channels: 4ch. Standard control. Heating and
MITSUBISHI
Temperature control module
L60TCRT4BW-CM


Temperature measurement resistor input. Number of input channels: 4ch. Detection function of broken
MITSUBISHI
Simple motion control module
LD77MS16


Control axis: maximum 16 axes. Operation cycle: 0.88ms, 1.77ms. Interpolation function: linear inter
MITSUBISHI
Simple motion control module
LD77MS4


Control axis: maximum 4 axes. Operation cycle: 0.88ms. Interpolation function: linear interpolation
MITSUBISHI
Simple motion control module
LD77MS2


Control axis: maximum 2 axes. Operation cycle: 0.88ms. Interpolation function: linear interpolation
MITSUBISHI
Multi function high speed I/O control module
LD40PD01


Input and output (DC/ differential). Input points: 12 points (DC5V/DC24V/ differential universal). P
MITSUBISHI
High speed counter module
LD62-CM


DC input. Number of input channels: 2Ch. DC5/12/24V input. Maximum count rate: pulse/s 200k. Linear
MITSUBISHI
High speed counter module
LD62D-CM


Number of input channels: 2Ch. Differential drive input. Maximum count rate: pulse/s 500K. Linear co
MITSUBISHI
Positioning module
LD75P1-CM


Open collector output. Axis of control: 1. Maximum output pulse: pulse/s 200k. Location data: 600 da
MITSUBISHI
CC-Link master / local station module
LJ61BT11-CM


CC-Link master / local station. Transmission speed: 10Mbps. Remote input / output: 8192 points. Remo
MITSUBISHI
DB A20 AnyWire master module
LJ51AW12D2


DB A20 AnyWire master station. Transmission distance: the longest 3km. Data input and output: up to
MITSUBISHI
SSCNET III /H host module
LJ72MS15-CM


SSCNET III /H remote station. Transmission speed: 150Mbps. End cap. Play the role of SSCNET III /H r
MITSUBISHI
Ethernet interface module
LJ71E71-100-CM


Transmission speed: 100Mbps/10Mbps. MELSOFT connection. SLMP cross letter (MC protocol). Communicati
MITSUBISHI
Serial communication module
LJ71C24-CM


RS-232, RS-422/485. Transmission speed: 230.4kbps. MC protocol. Communication protocol support funct
MITSUBISHI
Conversion module
FA-TB18XY


Can be used as a screw relay terminal.
MITSUBISHI
Conversion module
FA-LEB16XY


The terminal row is converted to e-CON.
MITSUBISHI
Conversion module
FA-LEB16XY-D


The terminal row is converted to e-CON.
MITSUBISHI
Terminal module
FA-TH16X24D31


Can be isolated to obtain DC24/48/100V, AC100/200V input signal.
MITSUBISHI
Terminal module
FA-TH16X100A31


Can be isolated to obtain DC24/48/100V, AC100/200V input signal.
MITSUBISHI
Terminal module
FA-TH16X200A31


Can be isolated to obtain DC24/48/100V, AC100/200V input signal.
MITSUBISHI
Terminal module
FA-TH16X24D31L


Can be isolated to obtain DC24/48/100V, AC100/200V input signal.
MITSUBISHI
Conversion module
FA-TB16XYPN


Can be used as a screw relay terminal.
MITSUBISHI
Conversion module
FA-TB16XYPN3


Can be used as a screw relay terminal.
MITSUBISHI
Conversion module
FA-TB1L16XYN


Can be used as a screw relay terminal. Positive common end use.
MITSUBISHI
Terminal module
FA-TH16X200A31L


Can be isolated to obtain DC24/48/100V, AC100/200V input signal.
MITSUBISHI
Terminal module
FA-TH16XRA20S


Can be isolated to obtain DC24/48/100V, AC100/200V input signal.
MITSUBISHI
Conversion module
FA-TB8XY1


Convert connector to screw relay terminal. According to the location of the connection equipment dis
MITSUBISHI
Conversion module
FA-TB8XY2


Convert connector to screw relay terminal. According to the location of the connection equipment dis
MITSUBISHI
Conversion module
FA-TB8XY3


Convert connector to screw relay terminal. According to the location of the connection equipment dis
MITSUBISHI
Conversion module
FA-TB16XY1


Convert connector to screw relay terminal. According to the location of the connection equipment dis
MITSUBISHI
Conversion module
FA-TB16XY2


Convert connector to screw relay terminal. According to the location of the connection equipment dis
MITSUBISHI
Conversion module
FA-TB16XY1N


Convert connector to screw relay terminal. According to the location of the connection equipment dis
MITSUBISHI
Conversion module
FA-TB32XY


The connector is converted to a screw relay terminal.
MITSUBISHI
Conversion module
FA-TB1L32XY


The connector is converted to a screw relay terminal.
MITSUBISHI
Conversion module
FA-TB32XYH


Convert connector to screw relay terminal. The action of the signal of the conversion module is show
MITSUBISHI
Conversion module
FA-LEB32XY


Convert connectors to e-CON.
MITSUBISHI
Conversion module
FA-CB8XY1


Convert connectors to fast connectors. According to the location of the connection equipment distrib
MITSUBISHI
Conversion module
FA-CB8XY2


Convert connectors to fast connectors. According to the location of the connection equipment distrib
MITSUBISHI
Conversion module
FA-CB16XY1


Convert connectors to fast connectors. According to the location of the connection equipment distrib
MITSUBISHI
Conversion module
FA-CB16XY2


Convert connectors to fast connectors. According to the location of the connection equipment distrib
MITSUBISHI
Conversion module
FA-TB161ACC2


Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr out
MITSUBISHI
Terminal module
FA-TH16YRA11


Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr out
MITSUBISHI
Terminal module
FA-TH16YRA20


Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr out
MITSUBISHI
Terminal module
FA-TH16YRA11S


Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr out
MITSUBISHI
Terminal module
FA-TH16YRA21S


Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr out
MITSUBISHI
Terminal module
FA-TH16YRA20S


Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr out
MITSUBISHI
Terminal module
FA-TH16YRAC20S


Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr out
MITSUBISHI
Terminal module
FA-TH16YTL11S


Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr out
MITSUBISHI
Terminal module
FA-TH16YTH11S


Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr out
MITSUBISHI
Terminal module
FA-TH16YTL21S


Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr out
MITSUBISHI
Terminal module
FA-TH16YTR20S


Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr out
MITSUBISHI
Terminal module
FA-TH16YSR20S


Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr out
MITSUBISHI
Programmable logic controller CPU
R04CPU


Operation control mode: stored procedure repeated operation. Input / output points: 4096 points. Pro
MITSUBISHI
Programmable logic controller CPU
R08CPU


Operation control mode: stored procedure repeated operation. Input / output points: 4096 points. Pro
MITSUBISHI
Programmable logic controller CPU
R04ENCPU


Operation control mode: stored procedure repeated operation. Built in IE CC-Link. Input / output poi
MITSUBISHI
Programmable logic controller CPU
R08ENCPU


Operation control mode: stored procedure repeated operation. Built in IE CC-Link. Input / output poi
MITSUBISHI
Programmable logic controller CPU
R16ENCPU


Operation control mode: stored procedure repeated operation. Built in IE CC-Link. Input / output poi
MITSUBISHI
Programmable logic controller CPU
R120ENCPU


Operation control mode: stored procedure repeated operation. Built in IE CC-Link. Input / output poi
MITSUBISHI
Movement CPU
R32MTCPU


"Axis of control: 32. Program language: motion SFC, special instruction. Servo program capacity: 32K
MITSUBISHI
Safety CPU
R08SFCPU-SET


Safety grade (SIL): SIL 3 (IEC 61508). Performance level (PL): e PL (13849-1 EN/ISO). Operation cont
MITSUBISHI
Safety CPU
R16SFCPU-SET