Professional sales of MITSUBISHI products
Home
Products
Price
Download
Supply
Replacement
Culture
Contact us
General search
Products
Price
Download
Supply
Home
>>
Products
Product catalogues
MITSUBISHI
Q series PLC
FX series PLC
L series PLC
Ans/QnAs series PLC
A/QnA series PLC
CC-Link module
MelsecNet/Mini module
R series PLC
Servo driver/Servo motor
Inverter
Touch Screen
QS safety series
CC-LINK IE network
Grid
List
All products
Hot search:
MR-RB50
HA-LFS701M
A73CPU
F920GOT-BBD-5-K-E
FR-F840-00930-2-60
A956WGOT-TBD
MITSUBISHI
The PC card interface unit connecting cable
A85GT-C05H
Cable length: 0.5 meters. For the GOT and the PC card interface unit (A1SD59J-MIF) connection. For F
MITSUBISHI
CRT connection cable
AC300VG
Cable length: 30 meters. For connection between GOT and CRT.
MITSUBISHI
A800 series to A900 series conversion line
A7GT-CNB-BUS-1
Bus connector conversion cable package
MITSUBISHI
A800 series to A900 series conversion line
A7GT-CNB-RS4-1
RS422 interface conversion cable package
MITSUBISHI
cpu module
L02SCPU-P
"Universal output function: source type. Program capacity: 20K step. Basic operations processing spe
MITSUBISHI
cpu module
L02CPU-P
"Universal output function: source type. Program capacity: 20K step. Basic operations processing spe
MITSUBISHI
cpu module
L06CPU-P
"Universal output function: source type. Program capacity: 60K step. Basic operations processing spe
MITSUBISHI
cpu module
L26CPU-CM
"Universal output function: leakage type. Program capacity: 260K step. Basic operations processing s
MITSUBISHI
cpu module
L26CPU-P
"Universal output function: source type. Program capacity: 260K step. Basic operations processing sp
MITSUBISHI
cpu module
L26CPU-BT-CM
"Universal output function: leakage type. Program capacity: 260K step. Basic operations processing s
MITSUBISHI
End cap with ERR terminal
L6EC-ET-CM
Error output. Rated open and close voltage, current: DC24V, 0.5A. Minimum open and close load: DC5V,
MITSUBISHI
Display module
L6DSPU-C-CM
Display characters: 16 x 4 character line width. Display character: English letters and numbers (ful
MITSUBISHI
Extension cable
LC10E-CM
Cable length: 1.0m. Weight: 0.23kg. Definition 1: conductor by one or a plurality of mutually insula
MITSUBISHI
Power module
L63P-CM
Input power: DC24V. Output: DC5V, 5A. Power supply module can be directly pasted on the printed circ
MITSUBISHI
Power module
L63SP
Slim type non isolated. Input power: DC24V. Output: DC5V, 5A. Power supply module can be directly pa
MITSUBISHI
AC input module
LX28-CM
Input points: 8 points. Rated input voltage: AC100 ~ 120V. Common way: 8 point / public end. Input /
MITSUBISHI
DC input module
LX41C4-CM
Input points: 32 points. Rated input voltage: DC24V. Common way: 32 point / public end. Input / outp
MITSUBISHI
DC input module
LX42C4-CM
Enter points: 64 points. Rated input voltage: DC24V. Common way: 32 point / public end. Input / outp
MITSUBISHI
Contact output module
LY10R2-CM
Output points: 16 points. Rated output voltage: DC24V/AC240V. Rated open and close current: 2A/1 poi
MITSUBISHI
Bidirectional thyristor output module
LY20S6-CM
Output points: 16 points. Output form: bidirectional thyristor output. Rated output voltage: AC100 ~
MITSUBISHI
Bidirectional thyristor output module
LY28S1A-CM
Output points: 8 points. Output form: no public side (all points independent). Rated output voltage:
MITSUBISHI
Transistor output module (drain type)
LY40NT5P-CM
Output points: 16 points. Output type: leakage type. Rated output voltage: DC12 ~ 24V. Max load curr
MITSUBISHI
Transistor output module (drain type)
LY42NT1P-CM
Output points: 64 points. Output type: leakage type. Rated output voltage: DC12 ~ 24V. Max load curr
MITSUBISHI
Transistor output module (source)
LY41PT1P-CM
Output points: 32 points. Output form: source type. Rated output voltage: DC12 ~ 24V. Max load curre
MITSUBISHI
Input / output mixed module
LH42C4NT1P-CM
Input points: 32 points. Input voltage: DC24V. Enter the public side of the way: 32 points / public.
MITSUBISHI
Multiple input (voltage / current / temperature) module
L60MD4-G-CM
Number of input channels: 4ch. Input voltage: DC - 10 - 10V. Input current: DC0 ~ 20mA. Input voltag
MITSUBISHI
Analog input module
L60ADVL8-CM
Number of input channels: 8ch. Input voltage: DC - 10 ~ 10V. Conversion speed: 1ms/ch. Resolution: 1
MITSUBISHI
Analog input module
L60ADIL8-CM
Number of input channels: 8ch. Input current: DC0 ~ 20mA. Conversion speed: 1ms/ch. Resolution: 1/80
MITSUBISHI
2 channel analog input module
L60AD4-2GH-CM
Number of input channels: 4ch. Input voltage: DC - 10 ~ 10V. Input current: DC0 ~ 20mA. Conversion s
MITSUBISHI
Analog output module
L60DA4-CM
Output channel number: 4ch. Output voltage: DC - 10 ~ 10V. Output current: DC0 ~ 20mA. Conversion sp
MITSUBISHI
Analog input / output module
L60AD2DA2-CM
Number of input channels: 2Ch. Input voltage: DC - 10 ~ 10V. Input current: DC0 ~ 20mA. Conversion s
MITSUBISHI
Temperature input module
L60RD8-CM
Number of input channels: 8ch. Input temperature resistance: Pt1000, Pt100, JPt100, Pt50, Ni500, Ni1
MITSUBISHI
Temperature control module
L60TCTT4BW-CM
Thermocouple input. Number of input channels: 4ch. Detection function of broken wire with heater. St
MITSUBISHI
Temperature control module
L60TCRT4-CM
Temperature measurement resistor input. Number of input channels: 4ch. Standard control. Heating and
MITSUBISHI
Temperature control module
L60TCRT4BW-CM
Temperature measurement resistor input. Number of input channels: 4ch. Detection function of broken
MITSUBISHI
Simple motion control module
LD77MS16
Control axis: maximum 16 axes. Operation cycle: 0.88ms, 1.77ms. Interpolation function: linear inter
MITSUBISHI
Simple motion control module
LD77MS4
Control axis: maximum 4 axes. Operation cycle: 0.88ms. Interpolation function: linear interpolation
MITSUBISHI
Simple motion control module
LD77MS2
Control axis: maximum 2 axes. Operation cycle: 0.88ms. Interpolation function: linear interpolation
MITSUBISHI
Positioning module
LD77MH16
MITSUBISHI
Positioning module
LD77MH4
MITSUBISHI
Multi function high speed I/O control module
LD40PD01
Input and output (DC/ differential). Input points: 12 points (DC5V/DC24V/ differential universal). P
MITSUBISHI
High speed counter module
LD62-CM
DC input. Number of input channels: 2Ch. DC5/12/24V input. Maximum count rate: pulse/s 200k. Linear
MITSUBISHI
High speed counter module
LD62D-CM
Number of input channels: 2Ch. Differential drive input. Maximum count rate: pulse/s 500K. Linear co
MITSUBISHI
Positioning module
LD75P1-CM
Open collector output. Axis of control: 1. Maximum output pulse: pulse/s 200k. Location data: 600 da
MITSUBISHI
CC-Link master / local station module
LJ61BT11-CM
CC-Link master / local station. Transmission speed: 10Mbps. Remote input / output: 8192 points. Remo
MITSUBISHI
DB A20 AnyWire master module
LJ51AW12D2
DB A20 AnyWire master station. Transmission distance: the longest 3km. Data input and output: up to
MITSUBISHI
SSCNET III /H host module
LJ72MS15-CM
SSCNET III /H remote station. Transmission speed: 150Mbps. End cap. Play the role of SSCNET III /H r
MITSUBISHI
Ethernet interface module
LJ71E71-100-CM
Transmission speed: 100Mbps/10Mbps. MELSOFT connection. SLMP cross letter (MC protocol). Communicati
MITSUBISHI
Serial communication module
LJ71C24-CM
RS-232, RS-422/485. Transmission speed: 230.4kbps. MC protocol. Communication protocol support funct
MITSUBISHI
Conversion module
FA-TB18XY
Can be used as a screw relay terminal.
MITSUBISHI
Conversion module
FA-LEB16XY
The terminal row is converted to e-CON.
MITSUBISHI
Conversion module
FA-LEB16XY-D
The terminal row is converted to e-CON.
MITSUBISHI
Terminal module
FA-TH16X24D31
Can be isolated to obtain DC24/48/100V, AC100/200V input signal.
MITSUBISHI
Terminal module
FA-TH16X100A31
Can be isolated to obtain DC24/48/100V, AC100/200V input signal.
MITSUBISHI
Terminal module
FA-TH16X200A31
Can be isolated to obtain DC24/48/100V, AC100/200V input signal.
MITSUBISHI
Terminal module
FA-TH16X24D31L
Can be isolated to obtain DC24/48/100V, AC100/200V input signal.
MITSUBISHI
Conversion module
FA-TB16XYPN
Can be used as a screw relay terminal.
MITSUBISHI
Conversion module
FA-TB16XYPN3
Can be used as a screw relay terminal.
MITSUBISHI
Conversion module
FA-TB1L16XYN
Can be used as a screw relay terminal. Positive common end use.
MITSUBISHI
Terminal module
FA-TH16X200A31L
Can be isolated to obtain DC24/48/100V, AC100/200V input signal.
MITSUBISHI
Terminal module
FA-TH16XRA20S
Can be isolated to obtain DC24/48/100V, AC100/200V input signal.
MITSUBISHI
Conversion module
FA-TB8XY1
Convert connector to screw relay terminal. According to the location of the connection equipment dis
MITSUBISHI
Conversion module
FA-TB8XY2
Convert connector to screw relay terminal. According to the location of the connection equipment dis
MITSUBISHI
Conversion module
FA-TB8XY3
Convert connector to screw relay terminal. According to the location of the connection equipment dis
MITSUBISHI
Conversion module
FA-TB16XY1
Convert connector to screw relay terminal. According to the location of the connection equipment dis
MITSUBISHI
Conversion module
FA-TB16XY2
Convert connector to screw relay terminal. According to the location of the connection equipment dis
MITSUBISHI
Conversion module
FA-TB16XY1N
Convert connector to screw relay terminal. According to the location of the connection equipment dis
MITSUBISHI
Conversion module
FA-TB32XY
The connector is converted to a screw relay terminal.
MITSUBISHI
Conversion module
FA-TB1L32XY
The connector is converted to a screw relay terminal.
MITSUBISHI
Conversion module
FA-TB32XYH
Convert connector to screw relay terminal. The action of the signal of the conversion module is show
MITSUBISHI
Conversion module
FA-LEB32XY
Convert connectors to e-CON.
MITSUBISHI
Conversion module
FA-CB8XY1
Convert connectors to fast connectors. According to the location of the connection equipment distrib
MITSUBISHI
Conversion module
FA-CB8XY2
Convert connectors to fast connectors. According to the location of the connection equipment distrib
MITSUBISHI
Conversion module
FA-CB16XY1
Convert connectors to fast connectors. According to the location of the connection equipment distrib
MITSUBISHI
Conversion module
FA-CB16XY2
Convert connectors to fast connectors. According to the location of the connection equipment distrib
MITSUBISHI
Conversion module
FA-TB161ACC2
Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr out
MITSUBISHI
Terminal module
FA-TH16YRA11
Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr out
MITSUBISHI
Terminal module
FA-TH16YRA20
Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr out
MITSUBISHI
Terminal module
FA-TH16YRA11S
Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr out
MITSUBISHI
Terminal module
FA-TH16YRA21S
Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr out
MITSUBISHI
Terminal module
FA-TH16YRA20S
Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr out
MITSUBISHI
Terminal module
FA-TH16YRAC20S
Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr out
MITSUBISHI
Terminal module
FA-TH16YTL11S
Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr out
MITSUBISHI
Terminal module
FA-TH16YTH11S
Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr out
MITSUBISHI
Terminal module
FA-TH16YTL21S
Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr out
MITSUBISHI
Terminal module
FA-TH16YTR20S
Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr out
MITSUBISHI
Terminal module
FA-TH16YSR20S
Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr out
MITSUBISHI
Programmable logic controller CPU
R04CPU
Operation control mode: stored procedure repeated operation. Input / output points: 4096 points. Pro
MITSUBISHI
Programmable logic controller CPU
R08CPU
Operation control mode: stored procedure repeated operation. Input / output points: 4096 points. Pro
MITSUBISHI
Programmable logic controller CPU
R04ENCPU
Operation control mode: stored procedure repeated operation. Built in IE CC-Link. Input / output poi
MITSUBISHI
Programmable logic controller CPU
R08ENCPU
Operation control mode: stored procedure repeated operation. Built in IE CC-Link. Input / output poi
MITSUBISHI
Programmable logic controller CPU
R16ENCPU
Operation control mode: stored procedure repeated operation. Built in IE CC-Link. Input / output poi
MITSUBISHI
CPU
R08SFCPU
MITSUBISHI
CPU
R120PCPU
MITSUBISHI
Programmable logic controller CPU
R120ENCPU
Operation control mode: stored procedure repeated operation. Built in IE CC-Link. Input / output poi
MITSUBISHI
CPU
R16SFCPU
MITSUBISHI
CPU
R32PCPU
MITSUBISHI
Movement CPU
R32MTCPU
"Axis of control: 32. Program language: motion SFC, special instruction. Servo program capacity: 32K
MITSUBISHI
Safety CPU
R08SFCPU-SET
Safety grade (SIL): SIL 3 (IEC 61508). Performance level (PL): e PL (13849-1 EN/ISO). Operation cont
MITSUBISHI
Safety CPU
R16SFCPU-SET
Safety grade (SIL): SIL 3 (IEC 61508). Performance level (PL): e PL (13849-1 EN/ISO). Operation cont
LK
©Copyright
Fax:020-28029239
Contact us
|
Search terms