MITSUBISHI
Home >> Products >> MITSUBISHI >> L series PLC >> FA products >> FA-TH16XRA20S | MITSUBISHI Terminal module FA-TH16XRA20S

FA-TH16XRA20S | MITSUBISHI Terminal module FA-TH16XRA20S

MITSUBISHI FA-TH16XRA20S Manual And Instructions
FA-TH16XRA20S datasheetPDF datasheet

MITSUBISHI FA-TH16XRA20S Product information and technical parameters:
Brand: MITSUBISHI
Name: Terminal module
Model: FA-TH16XRA20S
Can be isolated to obtain DC24/48/100V, AC100/200V input signal.

The connector is converted to a screw relay terminal.Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output.Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output.Output points: 8 points.
Output form: no public side (all points independent) MITSUBISHI FA-TH16XRA20S.
Rated output voltage: AC100 ~ 240V FA-TH16XRA20S
Max load current: 1A/1 point.
Common way: no public side (all points of independence).
Input / output occupied points: 16 points (I/O distribution: output 16 points).
External wiring connection: 18 point terminal.
1, the switch quantity acquisition and switch control and RS-485 bus are isolated from each other, and isolated from the whole system MITSUBISHI FA-TH16XRA20S.
2, the power supply line has anti reverse connect function, once the wrong power line,
Will automatically cut off the power to protect the entire module is not damaged.
With over-voltage protection function, when the voltage is too high, automatic disconnection,
Protecting the entire module is not damaged.
3, RS-485 interface with 600W lightning protection and surge protection function, with 3000V photoelectric isolation MITSUBISHI FA-TH16XRA20S.
4, the use of Modbus protocol, good general, can be very convenient and other systems,
Customers can also according to their own personal needs, custom related agreements, convenient and flexible.
5, communication lines using RS-485 bus, support for multiple modules in parallel use,
Easy to expand the system, good scalability. Convert connector to screw relay terminal.
According to the location of the connection equipment distribution module. Positive common end use. Output points: 16 points.
Output form: source type.
Rated output voltage: DC12 ~ 24V.
Max load current: 0.5A/1 point.
Protection function: have.
Common way: 16 point / public end.
Input / output occupied points: 16 points (I/O distribution: output 16 points).
External wiring connection: 18 point terminal.
The switch input and output module is a device which can collect the inputt / output of the switch signal,
Digital I/O modules are often called FA-TH16XRA20S.
The switch signal is collected to the computer or the computer to send the relevant instructions through the RS-485 bus to control the switch of the switch,
Can alsso be carried out through the RS-485 bus communication,
Remote control switch FA-TH16XRA20S.
Communication protocol is a standard Modbus protocol or custom protocol.