MITSUBISHI
Home >> Products >> MITSUBISHI >> L series PLC >> FA products >> FA-TH16X24D31 | MITSUBISHI Terminal module FA-TH16X24D31

FA-TH16X24D31 | MITSUBISHI Terminal module FA-TH16X24D31

MITSUBISHI FA-TH16X24D31 Manual And Instructions
FA-TH16X24D31 datasheetPDF datasheet

MITSUBISHI FA-TH16X24D31 Product information and technical parameters:
Brand: MITSUBISHI
Name: Terminal module
Model: FA-TH16X24D31
Can be isolated to obtain DC24/48/100V, AC100/200V input signal.

Input power: AC100-240V.
Output: DC5V, 5A.
Power supply module can be directly pasted on the printed circuit board of the power supply,
The device is characterized in that a special integrated circuit (ASIC), a digital signal processor (DSP), a microprocessor, a memory, a field programmable gate array (FPGA), and other digital or analog loads are provided MITSUBISHI FA-TH16X24D31.
In general, this type of module is called the load point (POL) power supply system or the use of point power supply system (PUPS) FA-TH16X24D31
Because of the advantages of the modular structure,
The module power supply is widely used in switching devices, access devices, mobile communications, microwave communications and optical transmission, routers and other communication fields and automotive electronics, aerospace, etc MITSUBISHI FA-TH16X24D31. . Output points: 8 points.
Output form: no public side (all points independent).
Rated output voltage: AC100 ~ 240V.
Max load current: 1A/1 point.
Common way: no public side (all points of independence).
Input / output occupied points: 16 points (I/O distribution: output 16 points).
External wiring connection: 18 point terminal MITSUBISHI FA-TH16X24D31.
1, the switch quantity acquisition and switch control and RS-485 bus are isolated from each other, and isolated from the whole system.
2, the power supply line has anti reverse connect function, once the wrong power line,
Will automatically cut off the power to protect the entire module is not damaged.
With over-voltage protection function, when the voltage is too high, automatic disconnection,
Protecting the entire module is not damaged.
3, RS-485 interface with 600W lightning protection and surge protection function, with 3000V photoelectric isolation.
4, the use of Modbus protocol, good general, cann be very convenient and other systems,
Customers can also according to their own personal needs, custom related agreements, convenient and flexible FA-TH16X24D31.
5, communication lines using RS-485 bus, support for multiple modules in parallel usee,
Easy to expand the system, good scalability FA-TH16X24D31. Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output.