Convert connector to screw relay terminal.
According to the location of the connection equipment distribution module.
Convert connector to screw relay terminal.
According to the location of the connection equipment distribution module. Input points: 32 points.
Rated input voltage: DC24V.
Common way: 32 point / public end.
Input / output occupied points: 32 points (I/O distribution: 32 points).
External wiring connection mode: 40 pin connector MITSUBISHI FA-TB16XY2.
The input and output module is also called control module, which can output signal when there is control requirement,
Or provide a switch signal to the controlled device,
At the same time, the feedback signal of the equipment can be received to report to the host computer,
Is an important part of the fire alarm linkage system,
The input and output modules in the market can provide a pair of passive normally open / normally closed contacts,
For controlling the controlled equipment, the module of the part can be set by the parameters,
Set to active output, corresponding to the two input and output modules, multiple input and output modules, and so on MITSUBISHI FA-TB16XY2
FA-TB16XY2 Convert connectors to fast connectors.
According to the location of the connection equipment distribution module MITSUBISHI FA-TB16XY2. Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output.Convert connectors to e-CON.AnyWireASLINK master station.
Transmission distance: the longest 200m.
Data input and output: up to 512 points.
Connect up to 128 units.
Enter 256 points, 256 points out of the output.
Connecting the input and output of the sensor to the programmable controller.
Ultra small sensor can be freely configured to control the input and output of 512 points.
In addition, the sensor can be supplied with a AnyWireASLINK transmission line (2 lines) by means of communication,
So as to facilitate additional sensor.
And can also be through the engineering software Works2 GX batch management sensor disconnection detection and from the station module settings, etc.,
Can significantly reduce the engineering hours.
Basic composition.
AnyWireASLINKAnyWireASLINK can be selected according to the load current of 2 wire or 4 wire from the station module.
In addition to the 2 wire type, thee local power supply can be connected with the 4 wire type mixed use FA-TB16XY2.
2 wire type.
The load current is less than that of the hour, by using the non isolated 2 wire type from the station module,
Easy connection without using local power suupply FA-TB16XY2.
4 wire type
By using isolated 4 wire type from the station module, the local power supply can be used,
Can support the use of more current load.