MITSUBISHI
Home >> Products >> MITSUBISHI >> L series PLC >> FA products >> FA-TH16YRAC20S | MITSUBISHI Terminal module FA-TH16YRAC20S

FA-TH16YRAC20S | MITSUBISHI Terminal module FA-TH16YRAC20S

MITSUBISHI FA-TH16YRAC20S Manual And Instructions
FA-TH16YRAC20S datasheetPDF datasheet

MITSUBISHI FA-TH16YRAC20S Product information and technical parameters:
Brand: MITSUBISHI
Name: Terminal module
Model: FA-TH16YRAC20S
Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output.

Convert connector to screw relay terminal.
According to the location of the connection equipment distribution module. The terminal row is converted to e-CON.Number of input channels: 8ch.
Input current: DC0 ~ 20mA.
Conversion speed: 1ms/ch.
Resolution: 1/8000.
By shifting the function easily when the system starts to fine tune the movement function MITSUBISHI FA-TH16YRAC20S.
Shift the set value to (shift to) the function of the digital output value FA-TH16YRAC20S
If you change the conversion value, the value is reflected in real time to the value of the scale (numeric value),
Can easily complete the fine-tuning of the system startup.
Extended detection method based on usage
Anomaly detection and extension of input signal
The detection method of the abnormal detection function of the input signal can be extended to detect the abnormal detection function of the input signal which is outside the range of the set range MITSUBISHI FA-TH16YRAC20S.
For the detection of the lower limit or the upper limit of the input signal abnormality, or when the detection of the broken line is performed.
Enter range extension
Range of scalable input range.
Combined with the abnormal detection function of the input signal, the broken line can be easily detected MITSUBISHI FA-TH16YRAC20S. Number of input channels: 2Ch.
Input voltage: DC - 10 ~ 10V.
Input current: DC0 ~ 20mA.
Conversion speed: 80 s/ch.
Resolution: 1/12000.
Output channel number: 2Ch.
Output voltage: DC - 10 ~ 10V.
Output current: DC0 ~ 20mA.
Conversion speed: 80 s/ch.
Resolution: 1/12000.
Status of connected devices by means of alarm monitoring.
Alarm output function
Process alarm.
When the digital value is in the range of preset, the output alarm.
Change rate alarm.
The output value of the output value of the digital output is too large (greater than the rate of change of the alarm limit) or too small (less than the rate of change), the output alarm.
Achieve stability measurement
Inter channel isolation
Isolation between the channels, can prevent the connection of sensors in the channel between the cross talk, so as to achieve stable measurement.
High speed, smooth continnuous analog output FA-TH16YRAC20S.
Waveform output function
Equipped with the industry''s first waveform output function.
The pre prepared waveform data can be imported into the analog output module, and the function of the analog output is simulatted according to the set conversion period FA-TH16YRAC20S.
It is not affected by the sequential scan time, and it can realize the high speed and smooth analog output.


...More relevant models >>>>