FA-CB16XY2 | MITSUBISHI Conversion module FA-CB16XY2

MITSUBISHI FA-CB16XY2 Manual And Instructions
FA-CB16XY2 datasheetPDF datasheet

MITSUBISHI FA-CB16XY2 Product information and technical parameters:
Brand: MITSUBISHI
Name: Conversion module
Model: FA-CB16XY2
Convert connectors to fast connectors.
According to the location of the connection equipment distribution module.

Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output.Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output.Output points: 16 points.
Rated output voltage: DC24V/AC240V.
Rated open and close current: 2A/1 point MITSUBISHI FA-CB16XY2.
Common way: 16 point / public end.
Input / output occupied points: 16 points (I/O distribution: output 16 points) FA-CB16XY2
External wiring connection: 18 point terminal.
The switch input and output module is a device which can collect the input / output of the switch signal,
Digital I/O modules are often called.
The switch signal is collected to the computer or the computer to send the relevant instructions through the RS-485 bus to control the switch of the switch,
Can also be carried out through the RS-485 bus communication,
Remote control switch MITSUBISHI FA-CB16XY2.
Communication protocol is a standard Modbus protocol or custom protocol. Can be isolated to obtain DC24/48/100V, AC100/200V input signal.Output channel number: 4ch.
Output voltage: DC - 10 ~ 10V.
Output current: DC0 ~ 20mA.
Conversion speed: 20 s/ch MITSUBISHI FA-CB16XY2.
Resolution: 1/20000.
Status of connected devices by means of alarm monitoring.
Alarm output function
Process alarm.
When the digital value is in the range of preset, the output alarm.
Change rate alarm.
The output value of the output value of the digital output is too large (greater than the rate of change of the alarm limit) or too small (less than the rate of change), the output alarm.
Achieve stability measurement
Inter channel isolation
Isolation between the channels, can prevent the connection of sensors in the channel between the cross talk, so as to achieve stable measurement.
High speed, smooth coontinuous analog output FA-CB16XY2.
Waveform output function
Equipped with the industry''s first waveform output function.
The pre prepared waveform data can be imported into the analog output module, and the function of the analog output is simulatted according to the set conversion period FA-CB16XY2.
It is not affected by the sequential scan time, and it can realize the high speed and smooth analog output.