Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output.
Can be isolated to obtain DC24/48/100V, AC100/200V input signal.Output points: 64 points.
Output form: source type.
Rated output voltage: DC12 ~ 24V.
Max load current: 0.1A/1 point.
Protection function: have.
Common way: 32 point / public end.
Input / output occupied points: 64 points (I/O distribution: output 64 points) MITSUBISHI FA-TH16YRA21S.
External wiring connection: 40 pin connector two.
The switch input and output module is a device which can collect the input / output of the switch signal,
Digital I/O modules are often called
FA-TH16YRA21S
The switch signal is collected to the computer or the computer to send the relevant instructions through the RS-485 bus to control the switch of the switch,
Can also be carried out through the RS-485 bus communication,
Remote control switch MITSUBISHI FA-TH16YRA21S.
Communication protocol is a standard Modbus protocol or custom protocol. SSCNET III /H remote station.
Transmission speed: 150Mbps.
End cap.
Play the role of SSCNET III /H remote station
SSCNET III /H host module is the MELSEC-L series of input and output modules and intelligent function modules connected to the SSCNET III /H module.
Can be used as a remote station of motion controller,
The flexible configuration of I/O module and intelligent function module is realized,
Reduce device wiring, save space MITSUBISHI FA-TH16YRA21S.
In addition, the module can be used for the input and output of the motion controller by the circulating transmission, and the module of the SSCNET III /H host module can be installed. Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output.Number of input channels: 2Ch.
Input voltage: DC - 10 ~ 10V.
Input current: DC0 ~ 20mA.
Conversion speed: 80 s/ch.
Resolution: 1/12000.
Output channel number: 2Ch.
Output voltage: DC - 10 ~ 10V.
Output current: DC0 ~ 20mA.
Conversion speed: 80 s/ch.
Resolution: 1/12000.
Status of connected devices by means of alarm monitoring.
Alarm output function
Process alarm.
When the digital value is in the range of preset, the output alarm.
Change rate alarm.
The output value of the output value of the digital output is too large (greater than the rate of change of the alarm limit) or too small (less than the rate of change), the output alarm.
Achieve stability measurement
Inter channel isolation
Isolation between the channels, can prevent the connection of sensors in the channel between the cross talk, so as to achieve stable measurement.
High speed, smooth contiinuous analog output FA-TH16YRA21S.
Waveform output function
Equipped with the industry''s first waveform output function.
The pre prepared waveform data can be imported into the analog output module, and the function of the analog output is simulatted according to the set conversion period FA-TH16YRA21S.
It is not affected by the sequential scan time, and it can realize the high speed and smooth analog output.