Input points: 16 points.
Rated input voltage and frequency: DC24V.
Rated input current: 6.0mA.
Response time: 5 S ~ 70ms.
Common way: 8 point / public end (positive public end).
Interrupt function: have.
External wiring connection mode: 18 point screw terminal.
The input module is the most used module in the control system.
According to the input voltage, the input points of different, choose the most suitable user needs of the module.
1 modules are equipped with a variety of functions.
Can be through a single input module to 1 points for the unit to set the high speed response, interrupt input function.
In addition, the public end of the module can be freely selected as the common end of the positive pole and the negative pole.
It is not necessary to use different modules according to the input specifications and functions, and reduce the number of modules,
Therefore slot occupied quantity can be reduced by 20% than in the past, the deployment cost can be reduced by 60% compared with the previous.
The input and output module installation number: 12.
DIN guide rail mounting adapter type: R6DIN1.
Size (H) * (32.5mm) * (W) * (D): * 439mm * 101mm. "Capacity: 4MB.Input: DC input.
Input points: 32 points.
Rated input voltage: DC24V
Rated input current: 4 TYP.
Response time: 0.1 ~ 70ms.
Common way: 32 points, the public side MITSUBISHI RX40PC6H.
Interrupt function: have.
Output: Transistor (drain type) output
RX40PC6H
Output points: 32 points
Rated load voltage: DC12 ~ 24V.
Max load current: 0.2A/ point.
Response time: 1ms.
Common way: 32 point / public end.
Protection function (overload, overheat)
Common。
External wiring connection: 40 pin connector two.
1 input / output hybrid modules can meet the functional requirements of both input and output modules MITSUBISHI RX40PC6H.
The function of the 2 modules is concentrated in 1 modules, which can help to save space and cost. Capacity: 2MB."The length of the cable: 5 meters.
IQ-R MELSEC series of "inter module synchronization", refers to the module can be in accordance with the synchronization cycle between modules,
The function of the input and output time synchronization of the multiple input and output modules and the intelligent function modules of the synchronization object MITSUBISHI RX40PC6H.
Using this function, the system and equipment can be controlled with high precision.
In addition, it is also available in the CC-LinkIE field network synchronous communication, so that the action time between the network nodes to maintain synchronization,
To avoid the error caused by the network transmission delay time, so as to build a stable system.
At the same time using these features, it can be easy to respond to the requirements of the high accuracy of the movement of the situation,
For example, the cutting and bending process of offset press, etc.. "1Gbps, fiber optic cable, management station / general station.
IE CC-Link controller network is a kind of controller network based on Gigabit Ethernet,
The most suitable for large scale controller decentralized control.
With high speed (1Gbps), large capacity (128K word), using the characteristics of the dual loop fiber,
Controller network system capable of constructing high reliability.
The fault prone high reliability fiber double loop network is not easy to be transmitted by using the double loop transmission of the strong anti interference fiber cable,
In the event of cable disconnection or power failure, etc., but also through the ring back function to continue communication.
Quick find line fault, module exception
The overall situation of the IE CC-Link controller network can be visualized by engineering software, and the circuit fault and module exception can be found quickly RX40PC6H.
Therefore, in case of failure, can quickly identify abnnormal parts, in order to shorten the system down time RX40PC6H.
In addition, the network can also monitor the status of other stations programmable controller.