Operation control mode: stored procedure repeated operation.
Built in IE CC-Link.
Input / output points: 4096 points.
Program capacity: 320K.
Program capacity of up to 1200K.
Multi CPU system for high precision motion control.
The built-in CPU module support 2 Gigabit Network port.
Database functions to facilitate data management.
Extended SRAM card with built-in security function.
Can be carried out a variety of motion control (position, speed, torque, advanced synchronous control, etc.).
In line with the international safety standards (13849-1 PL e ISO, IEC 61508 SIL 3) security CPU.
The most suitable for C/C++ language programming from the computer / computer environment for transplantation.
Standard interface.
The programmable controller CPU module has standard Ethernet port, USB port, SD card slot.
Ethernet port and USB port can be used to communicate with the corresponding peripheral devices,
SD memory card slot can be used to record data, databases and other data storage.
In addition, the expansion of the SRAM card can be used for the expansion of the capacity of the soft element / tag memory and used as a hardware security key.
Output points: 16 points.
Output form: Transistor (source) output.
Rated open and close voltage, current: -.
Rated load voltage: DC12 ~ 24V.
Max load current: 0.5A/ point.
Response time: 1ms.
Common way: 16 point / public end.
Protection function (overload, overheat).
External wiring connection mode: 18 point screw terminal MITSUBISHI R32ENCPU.
Output module with mechanical relay contact mechanism,
Including the load voltage range of the relay and can be used for the output of the DC12~24V load transistor output type
R32ENCPU
According to the load voltage, the output points of different, choose the most suitable user needs of the module.
Preventive maintenance based on the life of relay contact.
Relay output module can accumulate the number of ON of each output point MITSUBISHI R32ENCPU.
Through the understanding of the relay contacts of the number of times, according to the relay life of preventive maintenance. 1Gbps, fiber optic cable, management station / general station.
IE CC-Link controller network is a kind of controller network based on Gigabit Ethernet,
The most suitable for large scale controller decentralized control MITSUBISHI R32ENCPU.
With high speed (1Gbps), large capacity (128K word), using the characteristics of the dual loop fiber,
Controller network system capable of constructing high reliability.
The fault prone high reliability fiber double loop network is not easy to be transmitted by using the double loop transmission of the strong anti interference fiber cable,
In the event of cable disconnection or power failure, etc., but also through the ring back function to continue communication.
Quick find line fault, module exception
The overall situation of the IE CC-Link controller network can be visualized by engineering software, and the circuit fault and module exception can be found quickly.
Therefore, in case of failure, can quickly identify abnormal parts, in order to shorten the system down time.
In addition, the network can also monitor the status of other stations programmable controller. Data transmission speed: 1G/100M/10M: bps.
Interface: RJ45 connector (MDI/MDI-X AUTO).
Maximum frame size: 1518/9022 (when using mega frame).
IP version: IPv4: correspondence.
At the same time, the number of open connections: 128.
Fixed cache: 5K word x 16.
Cache for random access: 6K word x 1.
Communication cable: 1000BASE-T standard Ethernet cable: 5E class above, (with double shield, STP) through cable.
Ethernet interface module with 2 Ethernet ports,
Can be used as Ethernet, IE CC-Link controller network (metal cable), IE Field CC-Link network with communication port. In addition,
The module has been adopted to facilitate the identification of the positive words and graphic dot matrix LED,
In order to quickly identify the communication status of the network.
Equipped with 2 Gigabit Ethernet ports support,
Communication of Ethernet, IE CC-Link controller network (metal cable) or IE Field CC-Link network.
The 2 Ethernet ports can be used in combination with other networks.
1 modules can support 2 kinds of network such as Ethernet and IE Field CC-Link network, which can reduce the cost of network construction.
In addition, the Ethernet communication can be simultaneously open 128 connections, which can be connected to more support for Ethernet devices.
Can support a variety of network module products.
Based on IE 1Gbps CC-Link, 128K word high-speed, large capacity network.
1 modules support multiple networks.
Seamless communication through SLMP.
When an exception occurs, the communication can be continued through the ring back function.
Support RS-422/485, RS-232 and other standard interface.
IQ-R MELSEC series contains a variety of network modules and interface modules,
From the computer layer (production management, information system) to the field layer (equipment system), to provide the most suitable for the purpose and use of the network.
Open network IE CC-Link based on Ethernet is the core of the network.
IE CC-Link is an industrial open network with the flexible application of the world standard Ethernet technology,
Seamless connection can be realized from the controller layer to the field layer.
The use of SLMP, from the superior information system to the lower level of equipment, there is no need to consider the network layer.
Can be as 1 kinds of network generally seamless communication, whether in the offfice or in the field,
Can easily achieve information collection, equipment monitoring and maintenance R32ENCPU. In addition, using an Ethernet adapter module,
You can easily connect to the SLMP CC-Link universal Ethernet devices connected to the IEE Field network R32ENCPU.
Therefore, no need to add a new network can effectively use the visual sensor, RFID controller, such as a variety of Ethernet devices.