MITSUBISHI
Home >> Products >> MITSUBISHI >> QS safety series >> QS001CPU | MITSUBISHI Secure CPU module QS001CPU

QS001CPU | MITSUBISHI Secure CPU module QS001CPU

MITSUBISHI QS001CPU Manual And Instructions
QS001CPU datasheetPDF datasheet
QS001CPU Special InstructionsStrctured Programming Manual
QS001CPU Application FunctionsStrctured Programming Manual
QS001CPU Common InstructionsStrctured Programming Manual
QS001CPU FundamentalsStrctured Programming Manual
QS001CPU Multiple CPU SystemUser's Manual
QS001CPU Function Explanation, Program FundamentalsUser's Manual
QS001CPU Hardware Design, Maintenance and InspectionUser's Manual
QS001CPU Structured TextProgramming Manual
QS001CPU MELSAP-LProgramming Manual
QS001CPU SFCProgramming Manual
QS001CPU PID Control InstructionsProgramming Manual
QS001CPU Common Instructions 1/2Programming Manual
QS001CPU HardwareUser's Manual
QS001CPU Structured Text(ST)Programming Guide Book

MITSUBISHI QS001CPU Product information and technical parameters:
Brand: MITSUBISHI
Name: Secure CPU module
Model: QS001CPU
Control mode: loop program execution.
Input / output control mode: refresh mode.
Programming language: ladder diagram, function block.
Processing speed (CIS): 0.10 s.
Program capacity: 14k step.
Security PLC (secure programmable system) refers to the self or external components or the implementation of the failure of the agency,
Can still respond to and promptly cut off the output of the programmable system.
Different from ordinary PLC, security PLC not only can provide the function of ordinary PLC,
Safe control function can be realized,
Meet the requirements of the ISO 13849-1 EN and IEC 61508 control system safety related component standards.
PLC security market mainstream has oilz (Pilz) PSS 3000, PSS 4000,
PSS 4000 in addition to the security process can also be processed outside the standard control procedures.
All the components in the security PLC adopt the redundancy structure,
Two processor processing for cross detection,
The processing results of each processor are stored in their respective memory,
Output is only when the processing result is in full agreement,
If any inconsistency occurs during the process, the system is immediately shut down.

Safety installation number on the controller: up to 2 units (total WSO-GETH00200 and WSO-GCC100202)
Network type: Ethernet (TCP/IP).
Use special setting monitoring tools to configure the configuration directly.
Constitute a rich set of components can be easily and quickly set the hardware structure.
Creating logic for security devices, by using the automatically generated labels of the FB can easily create logic MITSUBISHI QS001CPU QS001CPU
Logical import and export.
You can store the connection settings of the input and output modules and the application logic created by the function block as a setting file,
Or read from a saved set file. Meet safety standards: EN954-1 class 4, 13849-1 PL e ISO.
Safe input points: 1 points (2 input) MITSUBISHI QS001CPU.
Start input points: 1.
Input type: P type (positive public end / positive public end input)
Safe output points: 1 points (3 output).
Spring clip terminal.
Additional security system.
Simply connect to the existing CC-LINK, you can add an independent security features.
Saving wiring by CC-link connection.
The wiring is not needed in particular to the condition monitoring of the safety relay module, and realizes the wiring of the cabinet and the other provinces MITSUBISHI QS001CPU.
Visualization of installation status.
Can monitor the safe output, as well as the safety input and the internal state of the relay, in the safety circuit to facilitate the identification of the reasons for the start. Board module installation location: QS series power module mounting slot.
Suitable substrate module: QS034B.
Input power: AC100~120V.
Security PLC (secure programmable system) refers to the self or external components or the implementation of the failure of the agency,
Can still respond to and promptly cut off the output of the programmable system.
Different from ordinary PLC, security PLC not only can provide the function of ordinary PLC,
Safe control function can be realized,
Meet the requirements of the ISO 13849-1 EN and IEC 61508 control system safety related component standards.
PLC security market mainstream has oilz (Pilz) PSS 3000, PSS 4000,
PSS 4000 in addition to the security process can also be processsed outside the standard control procedures QS001CPU.
All the components in the security PLC adopt the redundancy structure,
Two processor processing for cross detection,
The processing results of each processor are stored in their respective memoryy,
Output is only when the processing result is in full agreement,
If any inconsistency occurs during the process, the system is immediately shut down QS001CPU.


...More relevant models >>>>