MITSUBISHI
Home >> Products >> MITSUBISHI >> QS safety series >> QS0J71GF11-T2 | MITSUBISHI IE CC-Link live network master module and local module (with security features) QS0J71GF11-T2

QS0J71GF11-T2 | MITSUBISHI IE CC-Link live network master module and local module (with security features) QS0J71GF11-T2

MITSUBISHI QS0J71GF11-T2 Manual And Instructions
QS0J71GF11-T2 datasheetPDF datasheet
QS0J71GF11-T2 User's Manual
QS0J71GF11-T2 Safety Application Guide
QS0J71GF11-T2 Safety Guideline

MITSUBISHI QS0J71GF11-T2 Product information and technical parameters:
Brand: MITSUBISHI
Name: IE CC-Link live network master module and local module (with security features)
Model: QS0J71GF11-T2
"The most common station 11 units connected network: 121.
The 11 largest network connection units security station: 32.
Maximum network number: 239 sets.
Maximum secure connection of 1 units: 31 connection.
Security PLC (secure programmable system) refers to the self or external components or the implementation of the failure of the agency,
Can still respond to and promptly cut off the output of the programmable system.
Different from ordinary PLC, security PLC not only can provide the function of ordinary PLC,
Safe control function can be realized,
Meet the requirements of the ISO 13849-1 EN and IEC 61508 control system safety related component standards.
PLC security market mainstream has oilz (Pilz) PSS 3000, PSS 4000,
PSS 4000 in addition to the security process can also be processed outside the standard control procedures.
All the components in the security PLC adopt the redundancy structure,
Two processor processing for cross detection,
The processing results of each processor are stored in their respective memory,
Output is only when the processing result is in full agreement,
If any inconsistency occurs during the process, the system is immediately shut down. "

Category: Category 4 (EN/ISO13849-1), class 4 (EN954-1).
Security level: SIL, CL3 SIL3.
Performance level: PLe.
EFI connecting port number: 0.
EFI connection method: -.
Setting interface: RS-232.
Use special setting monitoring tools to configure the configuration directly.
Constitute a rich set of components can be easily and quickly set the hardware structure MITSUBISHI QS0J71GF11-T2.
Creating logic for security devices, by using the automatically generated labels of the FB can easily create logic QS0J71GF11-T2
Logical import and export.
You can store the connection settings of the input and output modules and the application logic created by the function block as a setting file,
Or read from a saved set file. Speed of delivery: optional 156kbps/625kbps/2 MITSUBISHI QS0J71GF11-T2. 5Mbps/5Mbps/10Mbps.
Connect up to 64 sets of units.
Security PLC (secure programmable system) refers to the self or external components or the implementation of the failure of the agency,
Can still respond to and promptly cut off the output of the programmable system.
Different from ordinary PLC, security PLC not only can provide the function of ordinary PLC,
Safe control function can be realized,
Meet the requirements of the ISO 13849-1 EN and IEC 61508 control system safety related component standards MITSUBISHI QS0J71GF11-T2.
PLC security market mainstream has oilz (Pilz) PSS 3000, PSS 4000,
PSS 4000 in addition to the security process can also be processed outside the standard control procedures.
All the components in the security PLC adopt the redundancy structure,
Two processor processing for cross detection,
The processing results of each processor are stored in their respective memory,
Output is only when the processing result is in full agreement,
If any inconsistency occurs during the process, the system is immediately shut down. Meet safety standards: EN954-1 class 4, 13849-1 PL e ISO.
Safe input points: 1 points (2 input).
Start input points: 1.
Input type: P type (positive public end / positive public end input)
Safe output points: 1 points (3 output).
Spring clip terminal.
Additional security system.
Simply connect to the existing CC-LINK, you can add an independent security features.
Saving wiring by CC-link connnection QS0J71GF11-T2.
The wiring is not needed in particular to the condition monitoring of the safety relay module, and realizes the wiring of the cabinet and the other provinces.
Visualization of installation status.
Can monitor the safe output,, as well as the safety input and the internal state of the relay, in the safety circuit to facilitate the identification of the reasons for the start QS0J71GF11-T2.


...More relevant models >>>>