MITSUBISHI
Home >> Products >> MITSUBISHI >> L series PLC >> FA products >> FA-TH16YRAB20SL | MITSUBISHI Terminal module FA-TH16YRAB20SL

FA-TH16YRAB20SL | MITSUBISHI Terminal module FA-TH16YRAB20SL

MITSUBISHI FA-TH16YRAB20SL Manual And Instructions
FA-TH16YRAB20SL datasheetPDF datasheet

MITSUBISHI FA-TH16YRAB20SL Product information and technical parameters:
Brand: MITSUBISHI
Name: Terminal module
Model: FA-TH16YRAB20SL
Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output.

CC-Link/LT master station.
Transmission speed: 2.5Mbps.
Remote input / output: 1024 points.
16 point mode.
In the cabinet, the device can also respond to high speed.
CC-Link/LT link scan time to reach the highest 1.2ms (2.5Mbps) at 64 stations,
Excellent response performance is achieved.
Can be selected according to the transmission distance 2 MITSUBISHI FA-TH16YRAB20SL. 5Mbps, 625kbps, 156kbps.
Comfortable environment without network awareness FA-TH16YRAB20SL
Parameter settings that do not require any trouble.
Moreover, the transmission speed only through the master module to set, can easily use the remote I/O. Transmission speed: 100Mbps/10Mbps.
MELSOFT connection.
SLMP cross letter (MC protocol).
Communication protocol support function MITSUBISHI FA-TH16YRAB20SL.
E-mail function.
Web function.
Collect / change CPU module data from the other side of the device.
SLMP (MC protocol) communication
SLMP is a protocol that uses Ethernet to access SLMP devices from the other device.
If it is possible to follow the SLMP control procedures to send and receive messages to the device,
The communication can be carried out by SLMP. MC can also support the previous agreement MITSUBISHI FA-TH16YRAB20SL.
MELSOFT connection
Can be connected with the programming tool Works2 GX and other MELSOFT products.
In addition, through the use of communication tools to support the sale of (MX Component),
Regardless of the details of the protocol (how to send and receive procedures),
Can create a communication program on the upper side of the system.
It can easily connect to BACnet and MODBUS /TCP
Communication protocol support function
Through the Works2 GX communication protocol support function, can easily set the communication with the other equipment required for the agreement. Convert connectors to fast connectors.
According to the location of the connection equipment distribution module. Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output.Output points: 64 points.
Output form: source type.
Rated output voltage: DC12 ~ 24V.
Max load current: 0.1A/1 point.
Protection function: have.
Common way: 32 point / public end.
Input / output occupied points: 64 points (I/O distribution: output 64 points).
External wiring connection: 40 pin connector two.
The switch input and output module is a device which can collect the input // output of the switch signal,
Digital I/O modules are often called FA-TH16YRAB20SL.
The switch signal is collected to the computer or the computer to send the relevant instructions through the RS-485 bus to control the switch of the switch,
Can alsso be carried out through the RS-485 bus communication,
Remote control switch FA-TH16YRAB20SL.
Communication protocol is a standard Modbus protocol or custom protocol.