MITSUBISHI
Home >> Products >> MITSUBISHI >> L series PLC >> FA products >> FA-TH16X100D31L | MITSUBISHI Terminal module FA-TH16X100D31L

FA-TH16X100D31L | MITSUBISHI Terminal module FA-TH16X100D31L

MITSUBISHI FA-TH16X100D31L Manual And Instructions
FA-TH16X100D31L datasheetPDF datasheet

MITSUBISHI FA-TH16X100D31L Product information and technical parameters:
Brand: MITSUBISHI
Name: Terminal module
Model: FA-TH16X100D31L
Can be isolated to obtain DC24/48/100V, AC100/200V input signal.

Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output.Convert connectors to fast connectors.
According to the location of the connection equipment distribution module. DB A20 AnyWire master station.
Transmission distance: the longest 3km.
Data input and output: up to 1024 points MITSUBISHI FA-TH16X100D31L.
Connect up to 128 units.
Enter 512 points, 512 points out of the output FA-TH16X100D31L
Support environmental protection, high speed, long distance transmission and special distribution system to support the special flat cable, universal VCTF cable, universal single wire cable and other cable.
Using original transmission mode, there is almost no branch limit,
Supports the automatic track and ring transmission,
Can also create suitable for small and medium sized factory wiring system MITSUBISHI FA-TH16X100D31L.
Support remote I/O, analog quantity, temperature and humidity terminal, anti false operation terminal and other equipment.
Up to 128 units from the station module
Can connect up to 128 units from the station module, for up to 1024 points (input 512 points / output 512 points) of the I/O control MITSUBISHI FA-TH16X100D31L.
In addition, the parameters can be set through the switch, easy to set the transmission distance of 50m/200m/1km/3km. Output points: 16 points.
Rated output voltage: DC24V/AC240V.
Rated open and close current: 2A/1 point.
Common way: 16 point / public end.
Input / output occupied points: 16 points (I/O distribution: output 16 points).
External wiring connection: 18 point terminal.
The switch input and output module is a device which can collect the input / output of the switch signal,
Digital I/O modules are often called.
The switch signal is collected to the computer or the computer to send the relevant instructions through the RS-485 bus to control the switch of the switch,
Can also be carried out through the RS-485 bus communication,
Remote control switch.
Communication protocol is a standard Modbus protocol or custom protocol. "Universal output function: source type.
Program capacity: 20K step.
Basic operations processing speed: 60ns.
Communication interface: USB/RS-232.
Control mode: stored procedure repeated operation.
Input / output points: 1024 points.
End cap.
Unable to install display module (L6DSPU-C-CM), RS-232 adapter, RS-422/485 adapter.
CPU built-in functions can be easily set through programming tools.
The built-in I/O function settings can be easily carried out through the parameters of the programming tool.
5 s units can be used for high precision workpiece measurement in pulse measurement mode,
Can be used with a minimum of 5 s units of the input signal of the ON/OFF time (the shortest 200 s) for high precision measurement.
For example, after measuring the ON time of the sensor input,
The "moving speed" and "length" of the workpiece can be accuraately calculated " FA-TH16X100D31L.
High precision PWM control of the highest 200kHz.
In the PWM output mode, by setting the ON time and cycle time,
The duty cycle can be changed, and the minimum cycle time is 5 s.
In addition to lighting dimming coontrol, simple motor control and heater control,
Can also be used to require high resolution detection equipment, such as a wide range of oscillators FA-TH16X100D31L. "