MITSUBISHI
Home >> Products >> MITSUBISHI >> CC-Link module >> Other CC-Link modules >> CL2Y16-TP1C2V | MITSUBISHI Sensor connection type output module CL2Y16-TP1C2V

CL2Y16-TP1C2V | MITSUBISHI Sensor connection type output module CL2Y16-TP1C2V

MITSUBISHI CL2Y16-TP1C2V Manual And Instructions
CL2Y16-TP1C2V datasheetPDF datasheet

MITSUBISHI CL2Y16-TP1C2V Product information and technical parameters:
Brand: MITSUBISHI
Name: Sensor connection type output module
Model: CL2Y16-TP1C2V
Output type: transistor output, drain type.
Output points: 16 points.
OFF leakage current: 0.1mA.
Output protection function.
Rated load voltage / current: DC24V/0.1A.
External connection: 2 wire.
Sensor connection type.
Minimum size of industry.
When installing the module can choose to use the DIN guide rail or screw mounting.
3 wire sensor input.

Input type: AC input.
Input points: 16 points.
Enter the response time: 20ms the following.
Rated input voltage / current: AC100V/7mA.
External connection: 2 wire.
According to the external connection mode and the external equipment input and output specifications,
Choose from a rich product lineup.
Finger protection through the upper part of the terminal,
The human body will not be exposed to live parts,
Therefore, the terminal station type remote I/O module can be directly mounted to the machine tool MITSUBISHI CL2Y16-TP1C2V CL2Y16-TP1C2V Input voltage rating: AC100/120/230/240V
External connection mode: module power supply: Terminal 3 pin (M3 screw), communication line / module power supply unit.
Dedicated power supply for CC-LINK/LT system with built-in 2A power supply MITSUBISHI CL2Y16-TP1C2V. Input type: DC input, positive common end.
Input points: 16 points.
Enter the response time: 0.5ms/1.5ms the following.
Rated input voltage / current: DC24V/4mA.
External connection: 1 wire.
MIL connector type.
Minimum size of industry.
Relay terminal, terminal station conversion module and electromagnetic valve, etc. are connected to a simple MIL connector MITSUBISHI CL2Y16-TP1C2V.
Simply remove the connector can be replaced with a simple module.
Additional module power supply, I/O power sharing.
No additional I/O power supply, you can reduce the cost and set space. Input type: DC input, positive public end / negative public end.
Input points: 32 points.
Enter the response time: 10ms the following.
Rated input voltage / current: DC24V/5mA.
External connection: 1 wire.
A2C shape terminal.
Type of input and output terminal.
Shape and A2C input and output modules are identical (same mounting dimensions),
Machining and installing holes are not required. Output type: transistor output, drain type.
Output points: 32 points.
OFF leakage current: 0.1mA.
Output protection function: No.
Rated load voltage / current: DC12V/DC24V/0.5A.
External connection: 2 wire.
Spring clip terminnal CL2Y16-TP1C2V.
Do not need to be tightened further or locked with screws, which can reduce the working hours of wiring.
Using 2 pieces of structure of the terminal units, maintenance can be maintained in the same line under the condition of the replacement module CL2Y16-TP1C2V.
When installing the module can choose to use the DIN guide rail or screw mounting.
Can be used for the 3 wire sensor input wiring.