MITSUBISHI
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI AJ35PTF-56DT Manual AJ35PTF-56DT User's Manual

MITSUBISHI AJ35PTF-56DT Manual AJ35PTF-56DT User's Manual

Brand: MITSUBISHI
Product model: AJ35PTF-56DT
Name: I/O MODULE
Sort: User's Manual
File language: English
File size: 6.99MB
MELSECNET/B.
Twisted pair bus. Input type: DC input, positive common end.
Input points: 16 points.
Enter the response time: 1.5ms the following.
Rated input voltage / current: DC24V/6mA.
External connection: 3 wire.
Spring clamping terminal platform push type input module.
Input module with diagnostic function
The use of push type, do not need screw fastening, so can reduce the wiring hours AJ35PTF-56DT Manual AJ35PTF-56DT User's Manual AJ35PTF-56DT
Can be used for each 1 points to enter the wiring of the broken wire detection.
Wiring abnormality of external power supply can be confirmed.
Using 2 pieces of structure of the terminal units, maintenance can be maintained in the same line under the condition of the replacement module. Enter points: 64 points AJ35PTF-56DT Manual AJ35PTF-56DT User's Manual.
Input voltage: DC7V above.
Input response time: 16ms.
16 pin connector.
Output points: 64 points.
Output response time: 16ms.
Output type: transistor output.
32 pin connector.
Dynamic input and output.
Control solenoid valve required I/O points by the action principle of the solenoid valve can be known,
A single coil solenoid valve with PLC control to 2 input and 1 output,
A double coil solenoid valve requires 3 inputs and 2 outputs,
A button needs an input; a light sensitive switch needs 4 or 2 inputs,
A signal lamp needs 1 output, band switch,
Several bands are required for several inputs,
In general, a variety of position switches are required to take up 2 input points AJ35PTF-56DT Manual AJ35PTF-56DT User's Manual.
MITSUBISHI PLC is the main product in the production of MITSUBISHI motor in Dalian.
It uses a kind of programmable memory for its internal storage procedures,
Execute logic operation, sequence control, timing, counting and arithmetic operations, user oriented instruction,
And through digital or analog input / output control of various types of machinery or production process.
The number of I/O thyristor DC motor control required tube DC motor speed control system is the main form of DC speed regulation,
The thyristor rectifier unit is used to supply power to the DC motor.
PLC control of the DC drive system, the input of the PLC in addition to the main signal outside the signal,
We need to consider the switching signal, the fault signal transmission device, brake signal and fan faullt signal AJ35PTF-56DT Manual AJ35PTF-56DT User's Manual.
The output of the PLC mainly consider the speed command signal positive 1~3 level, 1~3 level, allowing reverse switching signal and brake open signal etc..
In general, a reversible DC drivee system controlled by PLC is approximately 12 input points and 8 output points,
An irreversible DC drive system requires 9 inputs and 6 output points AJ35PTF-56DT Manual AJ35PTF-56DT User's Manual.
Related products
MITSUBISHI
AC input / relay output module
AJ35PTF-28AR
MITSUBISHI AC input / relay output module AJ35PTF-28AR
AC input points: 16 points. Input voltage and
MITSUBISHI
Melsecnet module
AJ35PTC-CNV
MITSUBISHI Melsecnet module AJ35PTC-CNV
MELSECNET/MINI -S3 data link system, A2C sy
MITSUBISHI
DC input / transistor output module
AJ35PTF-128DT
MITSUBISHI DC input / transistor output module AJ35PTF-128DT
DC input points: 64 points. Input voltage and