Name: I/O MODULE
Sort: User's Manual
File language: English
File size: 6.99MB
There are many A6TB models to different types of matching with the I/O module.
The cable can be connected to the I/O module of 32 points or 64 points by using the terminal row of the wire in advance.
These cables have a variety of lengths to be selected, so that
Using the module wiring and terminal is not only connected with the connector AJ35PTF-24T Manual AJ35PTF-24T User's Manual. Multi axis positioning controller AJ35PTF-24T
Program capacity: Max 60K step.
Input / output points: 1920 points.
The length of time required to execute the instruction, the length of the user''s program, the type of instruction, and the speed of the CPU execution are very significant,
Generally, a scanning process, the fault diagnosis time,
Communication time, input sampling and output refresh time is less,
The execution time is accounted for the vast majority of AJ35PTF-24T Manual AJ35PTF-24T User's Manual.
The photoelectric coupler is composed of two luminous two extreme tubes and a photoelectric transistor.
Light emitting diode two: the input of a photo coupler and the change of electrical signal,
The light signal is generated by the light emitting diode, which is the same as the input signal.
The working process of the input interface circuit: when the switch is closed, the diode light,
The transistor is then guided to the internal circuit and input signal under the irradiation of the light AJ35PTF-24T Manual AJ35PTF-24T User's Manual.
When the switch is off, the diode does not emit light, and the transistor is not on the way. Internal circuit input signal.
It is through the input interface circuit to the external switch signal into PLC internal can accept the digital signal.
Photoelectric three levels: in the light of the light signal conduction, the degree of light signal and the intensity of the light signal.
The output signal has a linear relationship with the input signal in the linear operating region of the photoelectric coupler.
User program storage capacity: it is a measure of how much the user appplication can store the number of indicators AJ35PTF-24T Manual AJ35PTF-24T User's Manual.
Usually in words or K words as units. 16 bit binary number is a word,
Every 1024 words are 1K words. PLC to store instructions and data in words.
General llogical operation instructions each account for 1 words AJ35PTF-24T Manual AJ35PTF-24T User's Manual. Timer / counter,
Shift instruction accounted for 2 words. Data operation instructions for 2~4.