Number of channels: 4 channels.
Sensing method and temperature range: PT100.
A1S64TC series component is a kind of temperature controller combined with ANS series CPU.
Components with temperature measurement input and built-in PID algorithm control output, can be used in a variety of temperature control occasions AJ35PTC-CNV-SI datasheet PDF catalog AJ35PTC-CNV-SI PDF datasheet.
Each component controls up to 4 loops at most
AJ35PTC-CNV-SI
Thermocouple input or PT100 3 wire temperature sensor input.
Control output switching signal for the output of the transistor.
BW is a signal with broken line detection function. I/O slots: 8 slots.
Could you install the power module.
Outline dimension: 420*130.
There are two types of extended floor,
A power module can be inserted, and the other one is not AJ35PTC-CNV-SI datasheet PDF catalog AJ35PTC-CNV-SI PDF datasheet.
The choice of any type of substrate depends on the total DC5V current consumption and the power supply on the CPU main substrate.
If the total demand is less than the power output, no additional power supply,
Then you can choose a more economical expansion board.
Both ends of the main base plate of the CPU have an expansion interface, and can be used for extending the cable connection AJ35PTC-CNV-SI datasheet PDF catalog AJ35PTC-CNV-SI PDF datasheet. Twisted pair cable.
Single bus.
Control unit.
According to the control requirements of the system, using the appropriate design method to design MITSUBISHI PLC program.
Procedures to meet the requirements of system control as the main line,
Write one by one to achieve the control function or the sub task of the program,
Gradually improve the functions specified by the system.
MITSUBISHI PLC initialization procedure. After MITSUBISHI PLC on power, the general need to do some of the initial operation,
In order to start making necessary preparations, to avoid the wrong operation of the system.
The main contents of the initialization program are: to some data area, counter and so on,
Data needed to restore some of the data area,
Set or reset some relays,
For some initial state display, etc.. Output points: 32 points.
Voltage: DC12/24V.
OFF leakage current: 0.1mA.
Output type: transistor output (type sink).
Response time: 2ms.
16 points / a common end.
38 point terminal station.
With the surge absorber.
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read.
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image register are changed with the change of the execution of the program.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay.
PLC selection with the development of PLC technology, more and more types of PLC products,
Function is becoming more and more perfect, and its application is more and more extensive.
Different series of different models of PLC has different performance, applicable occasions also have different emphasis,
Price also has a greater difference. Therefore PLC selection,
Under the premise of meeting the control requirements,
Should consider the best performannce to price ratio, a reasonable choice of PLC AJ35PTC-CNV-SI datasheet PDF catalog AJ35PTC-CNV-SI PDF datasheet.
System program memory for storing system program,
Including management procedures, monitoring procedures, as well as the user program tto do the compiler to compile the process of interpretation AJ35PTC-CNV-SI datasheet PDF catalog AJ35PTC-CNV-SI PDF datasheet.
Read only memory. Manufacturers use, content can not be changed, power does not disappear.