MITSUBISHI
Home >> Price >> MITSUBISHI >> FA-TH16YRA21 Market price | FA-TH16YRA21 Introduction
Brand sort

MITSUBISHI FA-TH16YRA21 Market price | FA-TH16YRA21 Introduction

Country: JAPAN
Name: Terminal module
Model: FA-TH16YRA21
Price: 0
MITSUBISHI FA-TH16YRA21
Drive: MR-H_ACN series CC-LINK features.
Rated output: 11KW.
The test system is composed of two parts, namely, the servo driver, the motor system and the host computer.
The host computer sends the speed command signal to the servo driver,
Servo drives start to run in accordance with the instructions.
In the course of operation, the running data of the servo system is collected by the host computer and the data acquisition circuit,
And carries on the preservation, the analysis and the display to the data FA-TH16YRA21 Because the motor is not loaded in this test system,
So compared with the previous two kinds of testing systems, the system has a relatively small volume,
And the measurement and control circuit of the system is relatively simple,
But it also makes the system can not simulate the actual operation of the servo drive.
Usually, such testing system is only used to test the rotational speed and angular displacement of the tested system under no-load condition,
And can not carry on the comprehensive and accurate test to the servo drive. Output points: 16 points.
Voltage: DC12/24V.
OFF leakage current: 0.1mA.
Output type: transistor output (type sink).
Response time: 2ms.
All points of independence.
38 point terminal station.
With the surge absorber.
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read.
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image register are changed with the change of the execution of the program.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay.
PLC selection with the development of PLC technology, more and more types of PLC products,
Function is becoming more and more perfect, and its application is more and more extensive.
Different series of different models of PLC has different performance, applicable occasions also have different emphasis,
Price also has a greater difference. Therefore PLC selection,
Under the premise of meeting the control requirements,
Should consider the best performance to price ratio, a reasonable choice of PLC.
System program memory for storing system program,
Including management procedures, monitoring procedures, as well as the user program to do the compiler to compile the process of interpretation.
Read only memory. Manufacturers use, content can not be changed, power does not disappear.
FA-TH16YRA21 Operation manual / Instructions / Catalog download link: /searchDownload.html?Search=FA-TH16YRA21&select=5


...more relevant model market price >>>>
Related products
MITSUBISHI
Terminal module
FA-TH16X24D31
MITSUBISHI Terminal module FA-TH16X24D31
Can e isolated to otain DC24/48/100V,
MITSUBISHI
Terminal module
FA-TH16YRA20SL
MITSUBISHI Terminal module FA-TH16YRA20SL
Can e isolated from the output of the p
MITSUBISHI
Terminal module
FA-TH16YTL21S
MITSUBISHI Terminal module FA-TH16YTL21S
Can e isolated from the output of the p
MITSUBISHI
Terminal module
FA-TH16YRA21
MITSUBISHI Terminal module FA-TH16YRA21
Can e isolated from the output of the p