MITSUBISHI
Home >> Products >> MITSUBISHI >> L series PLC >> FA products >> FA-TB16XY2N | MITSUBISHI Conversion module FA-TB16XY2N

FA-TB16XY2N | MITSUBISHI Conversion module FA-TB16XY2N

MITSUBISHI FA-TB16XY2N Manual And Instructions
FA-TB16XY2N datasheetPDF datasheet

MITSUBISHI FA-TB16XY2N Product information and technical parameters:
Brand: MITSUBISHI
Name: Conversion module
Model: FA-TB16XY2N
Convert connector to screw relay terminal.
According to the location of the connection equipment distribution module. Positive common end use.

Number of input channels: 8ch.
Input current: DC0 ~ 20mA.
Conversion speed: 1ms/ch.
Resolution: 1/8000.
By shifting the function easily when the system starts to fine tune the movement function.
Shift the set value to (shift to) the function of the digital output value.
If you change the conversion value, the value is reflected in real time to the value of the scale (numeric value),
Can easily complete the fine-tuning of the system startup MITSUBISHI FA-TB16XY2N FA-TB16XY2N
Extended detection method based on usage
Anomaly detection and extension of input signal
The detection method of the abnormal detection function of the input signal can be extended to detect the abnormal detection function of the input signal which is outside the range of the set range MITSUBISHI FA-TB16XY2N.
For the detection of the lower limit or the upper limit of the input signal abnormality, or when the detection of the broken line is performed.
Enter range extension
Range of scalable input range.
Combined with the abnormal detection function of the input signal, the broken line can be easily detected. Can be isolated to obtain DC24/48/100V, AC100/200V input signal MITSUBISHI FA-TB16XY2N. Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output.Output points: 16 points.
Rated output voltage: DC24V/AC240V.
Rated open and close current: 2A/1 point.
Common way: 16 point / public end.
Input / output occupied points: 16 points (I/O distribution: output 16 points).
External wiring connection: 18 point terminal.
The switch input and output module is a device which can collect the input / output of the switch signal,
Digital I/O modules are often called.
The switch signal is collected tto the computer or the computer to send the relevant instructions through the RS-485 bus to control the switch of the switch,
Can also be carried out through the RS-485 bus communication,
Remote control switch FA-TB16XY2N.
Communication protocol is a standard Modbus protocol or custom protocol FA-TB16XY2N. Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output.