MITSUBISHI
Home >> Price >> MITSUBISHI >> MR-J2M-8U6 Market price | MR-J2M-8U6 Introduction
Brand sort

MITSUBISHI MR-J2M-8U6 Market price | MR-J2M-8U6 Introduction

No PHOTO
Country: JAPAN
Name:
Model: MR-J2M-8U6
Price: 0
MITSUBISHI MR-J2M-8U6
Applicable motor capacity: 3.7KW.
Rated current: 1.2A.
Power supply voltage: three phase 400V.
Frequency converter and GOT supporting the use, to achieve a higher price.
SIMPLE GOT series can be directly connected to the IS70 series inverter.
GOT can be directly connected with the inverter. After connecting the two, the communication parameters can be automatically set.
In addition, the software can display the soft component of the control function in the GOT, even when the multi frequency converter is connected,
Can also be unified management with 1 GOT MR-J2M-8U6
Through the GOT screen to create software to import the picture data after the GOT,
Only use RS-422 connection GOT and frequency converter,
Can change the inverter speed / direction, monitoring the output frequency / output current and set a variety of parameters. Input and output points: 512 points.
Input / output data points: 8192 points.
Program capacity: 14K.
Basic command processing speed (LD command) s:0.20.
Integral type: the PLC components are installed together or a few pieces of printed circuit board,
And together with the power supply installed in the casing to form a single overall called the host or the basic unit, small, ultra small PLC using this structure.
Modular: PLC is the basic components of a separate module.
Medium and large PLC used this way. Easy maintenance.
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read.
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image register are changed with the change of the execution of the program.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay.
User program storage capacity: it is a measure of how much the user application can store the number of indicators.
Usually in words or K words as units. 16 bit binary number is a word,
Every 1024 words are 1K words. PLC to store instructions and data in words.
General logical operation instructions each account for 1 words. Timer / counter,
Shift instruction accounted for 2 words. Data operation instructions for 2~4.
MR-J2M-8U6 Operation manual / Instructions / Catalog download link: /searchDownload.html?Search=MR-J2M-8U6&select=5


...more relevant model market price >>>>
Related products