Output type: relay output.
Output points: 32 points.
OFF leakage current: -.
Output protection function: No.
Rated load voltage / current: DC24V/AC240V/2A.
External connection: 1 wire.
A2C shape terminal.
Type of input and output terminal.
Shape and A2C input and output modules are identical (same mounting dimensions),
Machining and installing holes are not required. Power: 30kw.
Purpose: to suppress the power harmonics
GT1020-LBL
Improve the power factor, reduce the input side of the high harmonic current.
Make sure that this option is installed in the FR-A820-03800 (75K) and FR-A840-02160 (75K) and above capacity and above capacity.
At the same time the installation options in the use of 75kW and above motor. (the IP55 series has a built-in DC reactor.)
According to the motor power used to select the DC reactor.
(when the inverter capacity is greater than the motor capacity, is still based on the motor capacity to choose.) Function: 4CH voltage / current output.
Adapter for connecting the left extension function of the CPU module.
CPU module can be connected to the left side up to 6 units. MITSUBISHI general purpose AC servo amplifier MELSERVO-J2-Super series.
Rated output: 0.2kw.
Built in positioning function.
Voltage: single phase AC100V.
Compatible with "MR-J2S- CP-S084" - servo amplifier and interface unit "MR-J2S-TO1" positioning by CC-Link
Simply setting the point table.
AC servo can be used as the driving source of the field network.
Using servo amplifier built-in positioning function, position data and speed data, you can set the CC-Link.
Start, stop and display can also be transmitted through the CC-Link.
Serial communication reduces wiring.
AC servo distributed control system can be easily constructed.Max input / output points: 32 points.
Supply voltage: 100 - 240VAC.
Input points: 16 points.
Output points: 16 points.
Output type: transistor.
Power consumption: 40VA.
Weight (kg):0.65.
Size (WxHxD) mm:150x90x87.
Note recording function, Component annotation can be recorded in the program register.
Online program editor, online change the program will not lose the working hours or stop production operation.
RUN/STOP switch, running on panel / stop switch easy to operate.
Remote maintenance, remote programming software can monitor, upload or uninstall programs and data via modem communications
Password protection, using a eight digit password to protect your program.
Clock function and hour meter function, all of the PLC FX2N has a real-time clock standard.
Continuous scanning function, to define the operation cycle for the application of the continuous scan time.
Input filter adjustment function, you can use the input filter to smooth the input signal (in the basic unit x000 to x017).
GT1020-LBL Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=GT1020-LBL&select=5