MITSUBISHI
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI Q24DHCCPU-LS Structured Text Manual Q24DHCCPU-LS Programming Manual

MITSUBISHI Q24DHCCPU-LS Structured Text Manual Q24DHCCPU-LS Programming Manual

Brand: MITSUBISHI
Product model: Q24DHCCPU-LS
Name: PLC
Sort: Programming Manual (Structured Text)
File language: English
File size: 4.20MB
8 modules can be installed.
Input / output points: 256 points.
Number of input and output elements: 8192.
Program capacity: 10K step.
Processing speed: 0.12 s.
Program memory capacity: 40 KB.
Support USB and RS232.
Unable to install memory card.
Own floor 8 slot.
Ultra high speed processing, production time is shortened, better performance Q24DHCCPU-LS Structured Text Manual Q24DHCCPU-LS Programming Manual Q24DHCCPU-LS
As applications become larger and more complex, it is necessary to shorten the system operation cycle time.
The operation period can be shortened by the super high basic operation speed 1.9ns.
In addition to achieve in the past with the control of single-chip high-speed control,
The system performance can be improved by reducing the total scan time,
To prevent any possible performance bias Q24DHCCPU-LS Structured Text Manual Q24DHCCPU-LS Programming Manual.
High speed and high precision data processing.
The processing speed of the real number (floating point) arithmetic has been greatly improved,
Addition instruction reached 0.014 mu s,
Therefore, it can support the request of high-speed, high-precision processing data processing.
In addition, the new addition of double precision floating point arithmetic instructions,
Simplify the programming, reduces the computational error when executing complex formula Q24DHCCPU-LS Structured Text Manual Q24DHCCPU-LS Programming Manual. Program capacity: 252 K step.
Input / output points: 4096 points.
Number of input and output elements: 8192.
Processing speed: 0.034 s.
Program memory capacity: 1008 KB.
Support USB and RS232.
CPU module expansion standard RAM (max 8MB).
Can be used with the SD memory card at the same time.
Continuous access file register.
Ultra high speed processing, production time is shortened, better performance.
As applications become larger and more complex, it is necessary to shorten the system operation cycle time.
The operation period can be shortened by the super high basic operation speed 1.9ns.
In addition to achieve in the past with the control of single-chip high-speed control,
The system performance can be improved by reducing the total scan time,
To prevent any possible performance bias.Output points: 32 points.
Output voltage and current: DC12~24V; 0.1A/ point; 2A/ common.
OFF leakage current: 0.1mA.
Response time: 1ms.
32 points and 1 common ends.
Source type.
40 pin connector.
With heat protection.
With the surge absorber.
With fuse.
With the help of sample tracking function, the starting time is shortened
By using the sampling and tracking function, it is convenient to analyze the data when the fault occurs,
Testing procedures for the time, etc., can shorten the time of failure analysis and start-up time.
In addition, the multi CPU system also helps to determine the data transceiver time between the CPU module.
Can be used to analyze the data collected by programming tools,
In the form of charts and trend charts, the data changes of the bit soft element and the word soft element can be easily displayed.
And the sampling tracking results can be stored in LogViewer GX form CSV,
By recording data display and analysis tool LogViewer GX to display.
Ultra high speed processing, production time is shortened, better performance.
As applications become larger and more complex, it is necessary to shorten the system operation cycle time.
The operation period can be shortened by the super high basic operation speed 1.9ns.
In addition to achieve in the past with the control of single-chip high-speed control,
The system performance can be improved by reducing the total scan time,
To prevent any possible performance bias.
Convenient processing of large capacity data.
In the past can not achieve the standard RAM and SRAM card file register area of continuous access,
The boundary of each area should be considered in programming.
The SRAM 8MB extension card is installed in the high speed universal QCPU,
Standard RAM can be used as a continuous file register,
Capacity up to 4736K words, thus simplifying the programming.
Thus, even if the memory space of the soft element is insufficient,
Can also be installed by the expansion of SRAM card, easy to extend the file register area.
The address register is extended to 32 bits, which can be programmed to go beyond the traditional 32K word,
And to achieve the extension to thee file register to all regions of the file register Q24DHCCPU-LS Structured Text Manual Q24DHCCPU-LS Programming Manual.
In addition, the processing speed of the index modification plays an important role in the efficient operation of structured daata (array),
The speed has been improved Q24DHCCPU-LS Structured Text Manual Q24DHCCPU-LS Programming Manual.
When the index is used to modify the program repeatedly (e.g. from FOR to NEXT), the scan time can be reduced.
Related products
MITSUBISHI
C language CPU
Q24DHCCPU-VG
MITSUBISHI C language CPU Q24DHCCPU-VG
Input / output points: 4096 points. Size side
MITSUBISHI
C language CPU
Q24DHCCPU-LS
MITSUBISHI C language CPU Q24DHCCPU-LS
Input / output points: 4096 points. Size side
MITSUBISHI
C language CPU
Q24DHCCPU-V
MITSUBISHI C language CPU Q24DHCCPU-V
Input / output points: 4096 points. Size side