8 channels.
Platinum thermal resistance (Pt100, JPt100).
Nickel thermal resistance (Ni100).
Shedding detection function.
Conversion speed: 320ms/8 channel.
Inter channel isolation.
40 pin connector.
Most suitable for process control of isolated analog modules.
Temperature data can be collected by connecting thermocouple / thermal resistance Q24DHCCPU-LS Special Instructions Manual Q24DHCCPU-LS Programming Manual Q24DHCCPU-LS
Products can choose multi-channel (8 channel) input type and channel isolation type.
Customers can choose the most suitable model according to the intended use.
Reduce system downtime recovery time.
With a simple operation, you can back up all the data in the CPU to the memory card.
Through regular backup, can be the latest parameters, procedures, etc. to save the storage card Q24DHCCPU-LS Special Instructions Manual Q24DHCCPU-LS Programming Manual.
In the event of a CPU failure, after the replacement of CPU, can be a simple operation,
Restore the system by using the data storage card in advance.
Therefore, it is not necessary to spend time to manage the backup data, but also can shorten the recovery time of the system shutdown.
Auto backup key data
Save the program and parameter files automatically to the program memory (ROM Flash) without using the backup battery,
To prevent the loss of the program and the parameters due to forgetting to replace the battery Q24DHCCPU-LS Special Instructions Manual Q24DHCCPU-LS Programming Manual.
In addition, the soft component data and other important data can be backed up to the standard ROM,
In order to avoid during the long holiday and other planned downtime,
The data is lost due to battery depletion.
The next time the power is turned on, the backup data will be automatically restored. Input: 2 channels.
Input: thermocouple / micro voltage / voltage / current.
Conversion speed (input):25ms/2 channel.
Sampling period: 25ms/2 channel.
Output: DC4~20mA.
Conversion speed (output):25ms/2 channel.
18 point terminal station.
With 5 kinds of PID control mode.
Loop control module suitable for fast response object control, such as temperature control, flow control, etc..
The loop control module has a PID control format and a sampling period of 25ms that is proportional to the speed,
Support high precision, high resolution Thermocouple Input, micro voltage input, voltage input, current input and current output.
The most suitable for high speed lift and temperature control and pressure control, flow control and other requirements of the application of high speed response.
Can be connected with JIS, IEC, NBS, ASTM standard thermocouple.
Through the small voltage, voltage, current input sensor, can be measured in a variety of input range of analog.
Provides the program control function, can according to the specific requirements of the time automatically change the target value (SV) and PID constant [proportional band (P), integratiion time (I), differential time (D)],
And cascade control function, allowing channel 1 as the main station, channel 2 for the control from the station Q24DHCCPU-LS Special Instructions Manual Q24DHCCPU-LS Programming Manual Q24DHCCPU-LS Special Instructions Manual Q24DHCCPU-LS Programming Manual.
Related products
MITSUBISHI
C language CPU
Q24DHCCPU-LS
MITSUBISHI C language CPU Q24DHCCPU-LS
Input / output points: 4096 points. Size side
MITSUBISHI
C language CPU
Q24DHCCPU-VG
MITSUBISHI C language CPU Q24DHCCPU-VG
Input / output points: 4096 points. Size side
MITSUBISHI
C language CPU
Q24DHCCPU-V
MITSUBISHI C language CPU Q24DHCCPU-V
Input / output points: 4096 points. Size side