MITSUBISHI
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI Q10UDEHCPU Structured Text Manual Q10UDEHCPU Programming Manual

MITSUBISHI Q10UDEHCPU Structured Text Manual Q10UDEHCPU Programming Manual

Brand: MITSUBISHI
Product model: Q10UDEHCPU
Name: PLC
Sort: Programming Manual (Structured Text)
File language: English
File size: 4.20MB
Input: 4 channels.
Thermocouple (K, J, T, B, S, E, R, N, U, L, PLlI, W5Re/W26Re,,).
Heater disconnection detection function.
Sampling period: 0.5s/4 channel.
18 point terminal table x2.
Can be flexible in various settings, to achieve the best temperature control of the temperature control module.
Equipment for high temperature control stability of extrusion molding machine,
The temperature regulating module has the function of preventing overheating and preventing over cooling Q10UDEHCPU Structured Text Manual Q10UDEHCPU Programming Manual Q10UDEHCPU
According to the control object device, select the standard control (heating or cooling) or the heating and cooling control (heating and cooling) mode.
In addition, the mixed control mode (combined with the standard control and heating - cooling control) can be selected Q10UDEHCPU Structured Text Manual Q10UDEHCPU Programming Manual.
Peak current suppression.
Can prevent the simultaneous opening of the output to control the peak current, which is helpful for saving energy and reducing the operation cost.
Heating function at the same time.
The multiple loop can reach the set value at the same time to carry out the uniform temperature control,
Helps to prevent no-load and effective energy saving and reduce operating costs Q10UDEHCPU Structured Text Manual Q10UDEHCPU Programming Manual.
Automatic adjustment function.
The PID constant can be adjusted automatically in the control process.
Automatic adjustment of cost (time, material and electrical energy) can be reduced. Adapter for mounting DIN guide rail (with anti vibration device).
For Q3*B, Q5*B, Q6*B, Q38RB, Q68RB, Q65WRB.PCI bus.
Support Japanese, English OS.
3C-2V/5C-2V coaxial cable.
Single bus controller network (control station / common station).
Province distribution network module in cabinet and device.
Link to connect the 64 stations when the fastest scanning time for 1.2ms (rate 2.5Mbps).
According to the transmission distance, the transmission rate is selected from 2.5Mbps, 625kbps and 156kbps.
CC-Link/LT from the station does not need any parameter settings.
Only need to set up the transmission speed in the master module, you can use the remote I/O.
I/O control in the first class of open field network module.
CC-Link based on reliable field bus technology,
Able to transmit large number of bits data (such as ONN/OFF information) and word data (such as analog information) Q10UDEHCPU Structured Text Manual Q10UDEHCPU Programming Manual.
Consistency of CC-Link to maintain loop transmission,
And the cycle of transmission and information (instantaneous transmmission) communication separately, so as to ensure the timeliness of Q10UDEHCPU Structured Text Manual Q10UDEHCPU Programming Manual.
Even if the information reaches saturation, it will not affect the link scan time.
Related products
MITSUBISHI
With Ethernet CPU
Q06UDEHCPU
MITSUBISHI With Ethernet CPU Q06UDEHCPU
Input / output points: 4096 points. Numer of
MITSUBISHI
With Ethernet CPU
Q26UDEHCPU
MITSUBISHI With Ethernet CPU Q26UDEHCPU
Input / output points: 4096 points. Numer of
MITSUBISHI
General purpose CPU
Q10UDHCPU
MITSUBISHI General purpose CPU Q10UDHCPU
Input / output points: 4096 points. Numer of
MITSUBISHI
With Ethernet CPU
Q10UDEHCPU
MITSUBISHI With Ethernet CPU Q10UDEHCPU
Input / output points: 4096 points. Numer of