Manual pulse generator /INC synchronous encoder input:
Use number: 3 sets of /1 modules.
Better user experience data recording function.
Easy to record, no need to program.
Simply through the special configuration tool wizard to easily complete the settings,
The collected data can be saved in CSV format to SD storage card Q00UJCPU-S8 Common Instruction 1/2 Manual Q00UJCPU-S8 Programming Manual.
Can be effectively used to save the CSV file to facilitate the creation of a variety of reference materials,
Including daily reports, generate reports and general reports
Q00UJCPU-S8
These data can be applied to the data analysis, tracing, etc..
To record the change of control data without missing.
Data can be collected in a time interval or in a millisecond time interval,
To record the change of the specified control data without any omission Q00UJCPU-S8 Common Instruction 1/2 Manual Q00UJCPU-S8 Programming Manual.
Therefore, in the event of failure, can quickly determine the cause, the precise action analysis."4 axes, SSCNET III type.
2 axis /4 axis /3 axis linear interpolation.
2 axis interpolation.
Control unit: mm, inch, degree, pulse.
Location data: 600 data / axis.
40 pin connector.
Through the SSCNET III cable connection to save wiring, the distance between the station up to 50m Q00UJCPU-S8 Common Instruction 1/2 Manual Q00UJCPU-S8 Programming Manual.
Absolute position system for determining the origin position is supported by the return data set operation.
In addition, the limit switch of the upper limit, the lower limit switch and the near point block signal input can be directly connected to the servo amplifier,
Thus greatly reducing the wiring requirements.
Easy to achieve high speed, high precision positioning control.
Support for multiple types of positioning control,
Including 2 ~ 4 axis 2 axis linear interpolation, circular interpolation, speed control and speed / position control, path switching control, constant speed control etc..
In addition, can use the "Configurator-QP GX" and other software,
Easy to set, monitor and debug. "Input voltage range: AC100-120V/AC200-240V.
Output voltage: DC5V.
Output power: 8.5A.
Simplified program debugging
Can use the software with the implementation of the conditions of the test function, any step in the program,
Changes the value of the soft component to a user specified value.
In the past, when debugging the specific loop process, the need to add a set of soft components of the program,
At present, through the use of the function, no need to change the program, you can make a specific loop program segment execution action.
Therefore, do not need to change the program separately in order to debug, debugging operation is more simple.
Auto backup key data
Save the program and parameter files automatically to the program memory (ROM Flash) without using the backup battery,
To prevent the loss of the program and the parameters due to forgetting to replace the battery.
In addition, the soft component data and other important data can be backed up to the standard ROM,
In order to avoid during the long holiday and other planned downttime,
The data is lost due to battery depletion Q00UJCPU-S8 Common Instruction 1/2 Manual Q00UJCPU-S8 Programming Manual.
The next time the power is turned on, the backup data will be automatically restored.
Through the expansion of soft components,, more convenient to create the program Q00UJCPU-S8 Common Instruction 1/2 Manual Q00UJCPU-S8 Programming Manual.
M soft components and B soft components can be expanded to 60K points, making the program easier to understand.