964此ID下载地址不存在3--/downloadfile/29-MELSEC-QL-Programming-(Common-88).pdf MITSUBISHI Q00JCPU-S8 Common Instruction 1/2 Manual Q00JCPU-S8 Programming Manual - MITSUBISHI
MITSUBISHI
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI Q00JCPU-S8 Common Instruction 1/2 Manual Q00JCPU-S8 Programming Manual

MITSUBISHI Q00JCPU-S8 Common Instruction 1/2 Manual Q00JCPU-S8 Programming Manual

Brand: MITSUBISHI
Product model: Q00JCPU-S8
Name: PLC
Sort: Programming Manual (Common Instruction 1/2)
File language: English
File size: 0.00MB
Input: 4 channels.
Thermocouple (C1602-1995 JIS).
Conversion speed: 40ms/1 channel.
18 point terminal station.
Most suitable for process control of isolated analog modules.
Temperature data can be collected by connecting thermocouple / thermal resistance.
Products can choose multi-channel (8 channel) input type and channel isolation type Q00JCPU-S8 Common Instruction 1/2 Manual Q00JCPU-S8 Programming Manual Q00JCPU-S8
Customers can choose the most suitable model according to the intended use.
Auto backup key data
Save the program and parameter files automatically to the program memory (ROM Flash) without using the backup battery,
To prevent the loss of the program and the parameters due to forgetting to replace the battery.
In addition, the soft component data and other important data can be backed up to the standard ROM,
In order to avoid during the long holiday and other planned downtime,
The data is lost due to battery depletion Q00JCPU-S8 Common Instruction 1/2 Manual Q00JCPU-S8 Programming Manual.
The next time the power is turned on, the backup data will be automatically restored.
Reduce system downtime recovery time.
With a simple operation, you can back up all the data in the CPU to the memory card.
Through regular backup, can be the latest parameters, procedures, etc Q00JCPU-S8 Common Instruction 1/2 Manual Q00JCPU-S8 Programming Manual. to save the storage card.
In the event of a CPU failure, after the replacement of CPU, can be a simple operation,
Restore the system by using the data storage card in advance.
Therefore, it is not necessary to spend time to manage the backup data, but also can shorten the recovery time of the system shutdown. 3C-2V/5C-2V coaxial cable.
Single bus.
Remote I/O net (remote I/O station).
MELSECNET/H network module capable of composing large scale flexible network system.
The MELSECNET/H network system includes the PLC network of the control station and the communication between the stations and the remote I/O network in the remote station remote I/O station.
Optical fiber loop system...... High speed communication of 10Mbps/25Mbps is realized.
The distance between stations, the length of the total cable length, sstrong anti-interference Q00JCPU-S8 Common Instruction 1/2 Manual Q00JCPU-S8 Programming Manual.
Coaxial bus system...... Using low cost coaxial cable, the network construction cost is lower than that of the optical fiber loop network.
Twisted pair bus system Q00JCPU-S8 Common Instruction 1/2 Manual Q00JCPU-S8 Programming Manual. ..... Combined with high performance price ratio network module and twisted pair cable,
The construction cost of network system is very low.
Related products
MITSUBISHI
CPU with base plate
Q00JCPU
MITSUBISHI CPU with base plate Q00JCPU
Program capacity: 8K step. Input / output poi
MITSUBISHI
CPU with base plate
Q00JCPU-S8
MITSUBISHI CPU with base plate Q00JCPU-S8
DC5V DC current consumption: 0.23A. Numer of
MITSUBISHI
Small points with substrate CPU
Q00JCPU-SET
MITSUBISHI Small points with substrate CPU Q00JCPU-SET
Input / output points: 256 points. Program ca