1 axis servo amplifier.
MITSUBISHI general AC servo amplifier MELSERVO-J4 series.
Rated output: 1.0kw.
Interface: SSCNET III /H.
Power supply: three phase AC200V.
Special specification: full closed loop control 4 wire / device end encoder ABZ phase input corresponding support function security unit, support positioning mode MR-J2-200A Manual MR-J2-200A Absolute Position Detection System Installation Guide
MR-J2-200A
Servo amplifier supporting SSCNET III /H.
Complete synchronization system capable of using high speed serial optical communication.
Can be combined with the servo system controller to maximize the performance of the servo system.
2 low frequency vibration can be suppressed at the same time by supporting the seismic algorithm of 3 inertial equipment.
Configurator2 MR to achieve convenient adjustment MR-J2-200A Manual MR-J2-200A Absolute Position Detection System Installation Guide.
Effectively restrain the low frequency aftershock effect produced by the front end of the boom or the main body of the device 100Hz.
Can effectively shorten the time to control the stability of the aftershock.
In the XY design of trajectory control, improve the accuracy of arc track.
At the same time, it can effectively control the phenomenon of quadrant protrusion caused by the rotation direction of the servo motor, which is caused by friction and twisting MR-J2-200A Manual MR-J2-200A Absolute Position Detection System Installation Guide. The length of the line: 30m.
IP level: IP67.
Bending life: high bending life.
Encoder cable for HF-KP/HF-MP/HF-SP/HF-JP/HC-LP/HC-UP series. Drive: MR-H_ACN series CC-LINK features.
Rated output: 0.4KW.
The test system is composed of two parts, namely, the servo driver, the motor system and the host computer.
The host computer sends the speed command signal to the servo driver,
Servo drives start to run in accordance with the instructions.
In the course of operation, the running data of the servo system is collected by the host computer and the data acquisition circuit,
And carries on the preservation, the analysis and the display to the data. Because the motor is not loaded in this test system,
So compared with the previous two kinds of testing systems, the system has a relatively small volume,
And the measurement and control circuit of the system is relativelyy simple,
But it also makes the system can not simulate the actual operation of the servo drive MR-J2-200A Manual MR-J2-200A Absolute Position Detection System Installation Guide.
Usually, such testing system is only used to test the rotational speeed and angular displacement of the tested system under no-load condition,
And can not carry on the comprehensive and accurate test to the servo drive MR-J2-200A Manual MR-J2-200A Absolute Position Detection System Installation Guide.