Power: 55kw.
Voltage: 400V.
The power factor of the input power factor is up to 0.99 and above (100% load).
Can be connected to multiple inverters, to achieve a common DC bus mode.
Equipped with standard power retrogradation function. Max input / output points: 128 points.
Supply voltage: 100 - 240VAC FX3G-40MR/DS Basic & Applied Instructions Edition Manual FX3G-40MR/DS PROGRAMMING MANUAL.
Input points: 64 points
FX3G-40MR/DS
Output points: 64 points.
Output type: transistor.
Power consumption: 100VA.
Weight (kg):1.8.
Size (WxHxD) mm:350x90x87.
Clock function and hour meter function, all of the PLC FX2N has a real-time clock standard.
Continuous scanning function, to define the operation cycle for the application of the continuous scan time.
Input filter adjustment function, you can use the input filter to smooth the input signal (in the basic unit x000 to x017) FX3G-40MR/DS Basic & Applied Instructions Edition Manual FX3G-40MR/DS PROGRAMMING MANUAL.
Note recording function, Component annotation can be recorded in the program register.
Since the FX2n series have the following features: the maximum range of inclusive of the standard features, program execution faster, the full complement of communication function, suitable for different countries in the world, and the power to meet a large number of special function modules of individual needs,
It can provide maximum flexibility and control capability for your factory automation applications FX3G-40MR/DS Basic & Applied Instructions Edition Manual FX3G-40MR/DS PROGRAMMING MANUAL.
Control 16~256 point.
Built in 8K capacity of the RAM memory, the maximum can be extended to 16K.
CPU arithmetic processing speed of 0.08 S/ basic instructions.
On the right side of the FX2N series can be connected to the input and output expansion modules and special function modules.
The basic unit is built in the 2 axis independent maximum 20kHz positioning function (transistor output type).
Quick disconnect the terminal block, which adopts excellent maintainability to quickly disconnect the terminal blocks, even if the cable is then replaced by the cable. MITSUBISHI inverter series: FR-A800.
Voltage level: three phase 400V.
Power: 450kw.
SLD converter rated current: 1094A.
Structure and function: the rectification part is off type.
Type: CA.
Substrate coating: have.
To maximize the performance of the motor.
Advanced auto tuning function.
The newly developed PM motor auto tuning feature can be used to operate other manufacturers of PM motors (Yong Ci synchronous motors) in the sensorless state.
Not only can drive MITSUBISHI induction motor and PM motor, but also can drive other manufacturers of induction motor and PM motor.
This means that you ccan reduce the cost of inventory and supplies FX3G-40MR/DS Basic & Applied Instructions Edition Manual FX3G-40MR/DS PROGRAMMING MANUAL.
If the PM motor is produced by a IPM motor or other company using MM-CF, the starting torque is limited to 50%,
EEven after tuning is not simple to use and positioning control of zero speed torque) induction motor and permanent magnet motor can be combined freely FX3G-40MR/DS Basic & Applied Instructions Edition Manual FX3G-40MR/DS PROGRAMMING MANUAL.