Function: RS-422 communication (GOT connection).
CPU module connected to the front of the expansion function of the substrate.
The front of the CPU module can be connected to 1 units at most. Series Name: F920GOT with buttons, with a series of effective functional modules.
System screen display language: japanese FX3G-40MT/DSS MODBUS Serial Communication Edition Manual FX3G-40MT/DSS USER'S MANUAL.
Display: 2
FX3G-40MT/DSS6 inches.
Display color: monochrome (blue / white).
Display device: LCD STN.
Resolution: 128 * 64.
Installation type: panel mounting.
The built-in communication port: RS-422 (1ch) /RS-232C (1ch).
Power supply voltage: DC5V.
The touch screen is the interface between people and machines in the field of information exchange and function contact or interact with each other,
Information exchange, functional contact or mutual influence, the hard contact and soft touch of a person and machine,
This interface includes not only the direct contact point, including long-distance information transmission and control function space FX3G-40MT/DSS MODBUS Serial Communication Edition Manual FX3G-40MT/DSS USER'S MANUAL.
The man-machine interface is the central link in the man-machine system,
Mainly from the safety engineering branch of the safety ergonomics to study and put forward the basis for the solution,
And over safety engineering equipment engineering,
Safety management engineering and safety systems engineering to study the specific solutions and measures of the safety of human computer science FX3G-40MT/DSS MODBUS Serial Communication Edition Manual FX3G-40MT/DSS USER'S MANUAL. MITSUBISHI inverter series: FR-F842.
Voltage level: three phase 400V.
Power: 560kw.
SLD converter rated current: 1212A.
Structure and function: the rectification part is off type.
Type: CA.
Substrate coating: have.
Energy saving by high efficiency motor.
Reduce standby power consumption.
DC24V external power supply, the input MC signal can be stopped after the motor for the OFF, in the motor drive for the ON.
Standby power management can be carried out by means of frequency converter to realize the power consumption reduction of standby time.
According to the temperature of tthe inverter cooling fan, the operation of the inverter can be controlled FX3G-40MT/DSS MODBUS Serial Communication Edition Manual FX3G-40MT/DSS USER'S MANUAL.
According to the operating conditions of the inverter cooling fan output the correspondinng signal,
Therefore, the inverter and other built-in fan and inverter cooling fan synchronous operation FX3G-40MT/DSS MODBUS Serial Communication Edition Manual FX3G-40MT/DSS USER'S MANUAL.
Can reduce the power consumption in the stop.