MITSUBISHI inverter series: FR-F820.
Voltage level: three phase 200V.
Power: 0.75kw.
SLD converter rated current: 7.7A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
Compatibility with existing models.
Transducer installation size and FR-F700 (P) series of the same, so you do not need to worry about the replacement operation FX2NC-96MT-D/UL Manual FX2NC-96MT-D/UL HARDWARE MANUAL
FX2NC-96MT-D/UL
(rectifier separation type will vary)
Also, but also through the use of options (FR-A8TAT), FR-F700 (P) series installed control loop terminal station.
Built in 2 PID arithmetic. In the inverter can be PID control of the motor state at the same time, used in the control of the external machine.
No external PID controller is used to control the external machine, so the system cost can be reduced FX2NC-96MT-D/UL Manual FX2NC-96MT-D/UL HARDWARE MANUAL. Max input / output points: 16 points.
Power supply voltage: 24VDC.
Input points: 8 points.
Output points: 8 points.
Output type: Transistor (source).
Power consumption: 25W.
Weight (kg):0.6.
Size (WxHxD) mm:130x90x86.
Built in CPU, power supply, input and output. By using a rich variety of functional extension boards and special adapters,
Can achieve high precision control FX2NC-96MT-D/UL Manual FX2NC-96MT-D/UL HARDWARE MANUAL.
Based on the function of FX2N has been greatly strengthened and enhanced.
High speed operation.
Basic instructions: 0.065 s/ instruction.
Application instruction: 0.642 s/ instruction.
Large capacity memory.
Built in program memory 64000 steps.
Flash memory cartridge with program transfer function.
Authentication。
Corresponding EN and UL/cUL authentication.
Faster and more efficient. Support high speed control and network communication, and have the function of data recording.
High speed, large capacity, multi-function high-end machine.
FX3U supports high speed processing, CC-Link communication, network communication, analog control and advanced positioning system.
Connected to the CC-Link, including the remote I/O, the maximum input and output control points up to 384 points,
Can correspond to a variety of field needs, the use of its scalabiliity and flexibility to expand the scope of application of the control system FX2NC-96MT-D/UL Manual FX2NC-96MT-D/UL HARDWARE MANUAL.
Third generation high function micro programmable controller.
High speed, high efficiency, high performance, large capacity, and new features FX2NC-96MT-D/UL Manual FX2NC-96MT-D/UL HARDWARE MANUAL.
Built in high speed processing and positioning.
Control points: maximum 256 points.
Use CC-Link remote I/O for 384 points.