Analog output channel number: 16CH.
Ambient temperature of 25 plus or minus 5 degrees C: plus or minus 0.1%.
Ambient temperature 0 ~ 55 degrees C:-.
Temperature coefficient: positive and negative 50ppm/.
Conversion speed: 1ms/CH.
Insulation between channels: isolation transformer insulation.
Output short circuit protection: have.
External power supply: -.
External wiring connection: 40 pin connector two.
Digital input value: 32000 ~ 32000.
Analog output voltage: DC - 10 - 10V.
Digital input value: 0 ~ 32000.
Analog output current: DC0 ~ 20mA.
Without using a special program to create the waveform, can reduce the programming time.
Easy to use parameters to set the conversion operation and scaling, no need to create a dedicated program.
Therefore, it is helpful to reduce the development cost of the program and to reduce the program capacity.
High speed output flow simulation waveform.
The analog output module has the function of registering arbitrary waveform data to the module, and continuously executing the analog output according to the set conversion cycle.
Execute the analog quantity (torque) control of stamping machine and injection molding machine, can automatically output the control waveform,
Through the process of high speed, smooth control. In addition, only prior to the waveform data are registered in the module,
Can easily control the analog waveform, so the production line control, such as repetitive control,
The input and output module installation number: 12.
Can install module: MELSEC-Q series module.
DIN guide rail mounting adapter type: Q6DIN1.
Size (H) * (44.1mm) * (W) * (D): * 439mm * 98mm.
Substrate module for mounting various modules of MELSEC-Q series.
Extended use of Q series expansion substrates in the following extensions MITSUBISHI R60DA16-G. "Output points: 16 points.
Output form: Transistor (drain type) output
R60DA16-G
Rated open and close voltage, current: -.
Rated load voltage: DC12 ~ 24V.
Max load current: 0.5A/ point.
Response time: 1ms.
Common way: 16 point / public end.
Protection function (overload, overheat).
External wiring connection mode: 18 point screw terminal.
Output module with mechanical relay contact mechanism,
Including the load voltage range of the relay and can be used for the output of the DC12~24V load transistor output type MITSUBISHI R60DA16-G.
According to the load voltage, the output points of different, choose the most suitable user needs of the module.
Preventive maintenance based on the life of relay contact.
Relay output module can accumulate the number of ON of each output point.
Through the understanding of the relay contacts of the number of times, according to the relay life of preventive maintenance MITSUBISHI R60DA16-G. 230.4kbps Max., RS-232 2 channel.
When using the serial communication module, it is only necessary to select from the communication protocol library of engineering software,
Can carry out data communication support MODBUS general agreement.
2 channels are supported 230.4kbps, communication can fully play the performance of the matching equipment. Data transmission speed: 1G/100M/10M: bps.
Interface: RJ45 connector (MDI/MDI-X AUTO).
Maximum frame size: 1518/9022 (when using mega frame).
IP version: IPv4: correspondence.
At the same time, the number of open connections: 128.
Fixed cache: 5K word x 16.
Cache for random access: 6K word x 1.
Communication cable: 1000BASE-T standard Ethernet cable: 5E class above, (with double shield, STP) through cable.
Ethernet interface module with 2 Ethernet ports,
Can be used as Ethernet, IE CC-Link controller network (metal cable), IE Field CC-Link network with communication port. In addition,
The module has been adopted to facilitate the identification of the positive words and graphic dot matrix LED,
In order to quickly identify the communication status of the network.
Equipped with 2 Gigabit Ethernet ports support,
Communication of Ethernet, IE CC-Link controller network (metal cable) or IE Field CC-Link network.
The 2 Ethernet ports can be used in combination with other networks.
1 modules can support 2 kinds of network such as Ethernet and IE Field CC-Link network, which can reduce the cost of network construction.
In addition, the Ethernet communication can be simultaneously open 128 connections, which can be connected to more support for Ethernet devices.
Can support a variety of network module products.
Based on IE 1Gbps CC-Link, 128K word high-speed, large capacity network.
1 modules support multiple networks.
Seamless communication through SLMP.
When an exception occurs, the communication can be continued through the ring back function.
Support RS-422/485, RS-232 and other standard interface.
IQ-R MELSEC series contains a variety of network modules and interface modules,
From the computer layer (production management, information system) to the field layer (equipment system), to provide the most suitable for the purpose and use of the network.
Open network IE CC-Link based on Ethernet is the core of the network.
IE CC-Link is an industrial open network with the flexible application of the world standard Ethernet technology,
Seamless connection can be realized from the controller layer to the field layer.
The use of SLMP, from the superior information system to the lower level of equipment, there is no need to consider the network layer.
Can be as 1 kinds of network generally seamless communication, whether in the offfice or in the field,
Can easily achieve information collection, equipment monitoring and maintenance R60DA16-G. In addition, using an Ethernet adapter module,
You can easily connect to the SLMP CC-Link universal Ethernet devices connected to the IEE Field network R60DA16-G.
Therefore, no need to add a new network can effectively use the visual sensor, RFID controller, such as a variety of Ethernet devices.