MITSUBISHI QX40-S1 Product information and technical parameters:
Brand: MITSUBISHI
Name: Type DC input module
Model: QX40-S1
Input points: 16 points.
Input voltage and current: 4mA DC24V.
Response time: 0.1/0.2/0.4/0.6/1ms.
16 point /1 a public side.
Common anode.
18 point terminal station.
A variety of modules with excellent performance,
Meet the needs of various control from analog to location.
Q series module products include a variety of types of I/O, analog and positioning function module.
Can fully meet the switch, sensor, such as the input and output, temperature, weight, flow and motor, drive control,
As well as the requirements of high-precision control of the positioning of the industry, the control needs of various fields.
Can also be used in combination with the CPU module to achieve appropriate control.
Continue to go beyond, to climb the peak of Q series.
Strengthen security function.
Can be set up to 32 characters of the file password.
In addition to the English letters, numbers, but also the use of special characters,
To further enhance the security of the password.
In addition, only pre registered devices are allowed to access CPU,
To intercept unauthorized access to unauthorized users.
Therefore, it is important to prevent the outflow of important program assets and protect intellectual property rights.
Easy connection programming tool via ethernet.
Programming tools (Works2 GX, Developer GX) and CPU direct connection (1 to 1),
No need to carry out the IP address settings. And there is no need to select the cable, the straight line and the cross line can be used.
Therefore, this connection method and the use of USB, can easily communicate with the CPU,
Even the operators are not familiar with the network settings can easily establish a connection.

2 channel.
Differential input: 40kpps/400kpps/800kpps/2Mpps/4Mpps/8Mpps.
Count input signal: EIA standard RS-422-A (differential line driver).
DC input: 10kpps/100kpps/200kpps.
Count input signal: DC5/12/24V 7 ~ 10mA.
External output: DC24V.
Consistent output: Transistor (drain), DC12/24V, 0.1A/ point, 0 MITSUBISHI QX40-S1. 8A/ common.
40 pin connector.
Multifunctional counting / timing module (QD65PD2)
Very precise positioning and tracking QX40-S1
Maximum count rate of up to 8Mpps (differential input 4 phase 2 frequency multiplication), is 2 times in the past.
Multifunctional and convenient use!
Pulse measuring function... Measurement resolution of 100ns, can be performed with high precision pulse measurement.
PWM output function MITSUBISHI QX40-S1. .. Configuration of the maximum 200 PWM kHz output function. Available 0.1 s single
Bit change duty cycle, to achieve ultra precise output control.
Cam switching function... The output of the 8 points, 16 step / output cam switch.
High precision timing control can be realized by cam switch.
Complete complex control using a consistent test!
Uniform output function... Can provide support for complex applications MITSUBISHI QX40-S1.
According to the specific circumstances, choose to use the cam switch function or the same output function.Three-phase 3 wire type.
Measuring circuit number: 4 circuits.
Measurement items: power consumption (consumption, regeneration), current, voltage, power, power factor, etc..
Power measurement module product group capable of simply measuring various energy information.
With only one module can be used to measure and power consumption (consumption and regeneration), reactive power, current, voltage, power, power factor and frequency of all kinds of detailed information.
No ladder program can continue to monitor the minimum and maximum values, can also perform 2 types of upper / lower limit alarm.
Only in the ON state can be used to measure the output of the output device.
Therefore, the amount of electricity and the quantity of electricity in the unit of the beat can be obtained during the operation of the equipment.
3 phase 3 wire products can bbe used to measure up to 4 circuits in one slot,
3 phase 4 wire products can be used to measure up to 3 circuits,
So the electrical energy measurement can be carried out in a small space by the multi circuit products QX40-S1.
For example, a module ccan be used to measure other loads from the control panel trunk QX40-S1.
In addition, Works2 GX (version 1.90U and higher) can be used to easily set parameters.