MITSUBISHI
Home >> Products >> MITSUBISHI >> CC-LINK IE network >> NZ2GFCM1-16TE | MITSUBISHI Modular remote transistor output module NZ2GFCM1-16TE

NZ2GFCM1-16TE | MITSUBISHI Modular remote transistor output module NZ2GFCM1-16TE

MITSUBISHI NZ2GFCM1-16TE Manual And Instructions
NZ2GFCM1-16TE datasheetPDF datasheet

MITSUBISHI NZ2GFCM1-16TE Product information and technical parameters:
Brand: MITSUBISHI
Name: Modular remote transistor output module
Model: NZ2GFCM1-16TE
Type: MIL connector.
Output form: transistor output, source.
Output points: 16 points.
Rated input voltage / current: DC12/24V (0.5A).
External connection: 1 wire.
By using the output ON number of times, it is convenient to confirm the total number of ON of each output point.
High speed input and output control of a single module can be realized by using first order logic function.
IE CC-Link field network remote equipment station. According to the equipment, more easily distributed input and output devices.
Can be connected to the expansion module, more convenient to expand the input and output points.
Support synchronous communication (using with simple motion control module).
According to the simple motion control module of the network (Master) control cycle of the implementation of the control cycle and its synchronization,
Implementation of multiple simultaneous action from the station.

Type: 18 point terminal.
Input type: DC input, the common cathode / negative public end sharing.
Input points: 16 points.
Rated input voltage / current: DC24V (6mA).
External connection: 1 wire.
Can be on the remote /O I module, analog module, high-speed counter module free extension of input and output points MITSUBISHI NZ2GFCM1-16TE.
The analog input module can be extended, and the sampling time of the analog and digital conversion values can be controlled by the external input signal NZ2GFCM1-16TE (trigger conversion function)
Scalable high-speed counter module, ON/OFF control in the implementation of accurate cycle. (cam switching function)
IE CC-Link field network remote equipment station. According to the equipment, more easily distributed input and output devices MITSUBISHI NZ2GFCM1-16TE.
Can be connected to the expansion module, more convenient to expand the input and output points.
Support synchronous communication (using with simple motion control module).
According to the simple motion control module of the network (Master) control cycle of the implementation of the control cycle and its synchronization,
Implementation of multiple simultaneous action from the station MITSUBISHI NZ2GFCM1-16TE. Type: sensor connector (e-CON).
Input form: DC input, positive pole common end.
Input points: 16 points.
Rated input voltage / current: DC24V (4mA).
External connection: 3 wire.
IE CC-Link field network module type remote unit.
Select input response time from 0ms/0.2ms/1ms/1.5ms/5ms/10ms/20ms/70ms.
High speed input and output control of single module can be realized by using first order logic function.
IE CC-Link field network remote equipment station. According to the equipment, more easily distributed input and output devices.
Can bee connected to the expansion module, more convenient to expand the input and output points NZ2GFCM1-16TE.
Support synchronous communication (using with simple motion control module).
According to the simple motion control module of the network (Mastter) control cycle of the implementation of the control cycle and its synchronization,
Implementation of multiple simultaneous action from the station NZ2GFCM1-16TE.


...More relevant models >>>>