FR-HAL-H11K | MITSUBISHI AC reactor FR-HAL-H11K

MITSUBISHI FR-HAL-H11K Manual And Instructions
FR-HAL-H11K datasheetPDF datasheet

MITSUBISHI FR-HAL-H11K Product information and technical parameters:
Brand: MITSUBISHI
Name: AC reactor
Model: FR-HAL-H11K
Power: 11kw.
Purpose: to suppress the power harmonics.
Connected to the inverter input, can be used to improve the power factor, reduce the input side of the high harmonic current.
According to the motor power used to select AC reactor.
(when the inverter capacity is greater than the motor capacity, is still based on the motor capacity to choose.)

Power: 15kw.
Voltage: 400V.
The power factor of the input power factor is up to 0.99 and above (100% load).
Can be connected to multiple inverters, to achieve a common DC bus mode.
Equipped with standard power retrogradation function. Power: 22kw.
Purpose: to suppress the power harmonics.
Improve the power factor, reduce the input side of the high harmonic current MITSUBISHI FR-HAL-H11K.
Make sure that this option is installed in the FR-A820-03800 (75K) and FR-A840-02160 (75K) and above capacity and above capacity FR-HAL-H11K
At the same time the installation options in the use of 75kW and above motor. (the IP55 series has a built-in DC reactor.)
According to the motor power used to select the DC reactor.
(when the inverter capacity is greater than the motor capacity, is still based on the motor capacity to choose MITSUBISHI FR-HAL-H11K. ) Power: 5.5kw.
Purpose: high frequency braking resistor.
The use rate of the built-in regenerative brake of the transducer can be promoted.
When using the FR-ABR type brake resistor, the short circuit piece between the terminal PR-PX is removed. Does not remove the short circuit chip will lead to overheating of the brake resistor MITSUBISHI FR-HAL-H11K.
The utilization rate of the regenerative braking should be less than the allowable brake use rate in the above table.
With the operating frequency of the brake resistor to reach 300 degrees C or higher, it is necessary to take protective measures and cooling.
MYS type resistor can be used. But please pay attention to the allowable brake use rate.
Do not remove the terminal P/+ and P1 between the short circuit chip, in addition to connecting the DC reactor.
The installation of thermal relay, to avoid overheating and burn the braking resistor. MITSUBISHI inverter FR-A740 series.
Voltage level: 3 phase 400V.
Frequency converter capacity: 162KW.
Frequency converter is the application of frequency conversion technology and micro electronics technology, by changing the motor operating power frequency mode to control the AC motor power control equipment.
The converter is composed of rectifier (AC), filter, inverter (DC), braking unit, driving unit, micro processing unit of thhe detection unit FR-HAL-H11K.
Inverter by the internal IGBT to adjust the output power supply voltage and frequency,
According to the actual needs of the motor to provide the required power supply voltage, and then achieve the purpose of energy savving, speed control, in addition to the,
Inverter has a lot of protection functions, such as over current, over voltage, overload protection and so on FR-HAL-H11K.