MITSUBISHI
Home >> Products >> MITSUBISHI >> CC-Link module >> Remote I/O module >> AJ65VBTCE2-16T | MITSUBISHI Sensor connector type transistor output module AJ65VBTCE2-16T

AJ65VBTCE2-16T | MITSUBISHI Sensor connector type transistor output module AJ65VBTCE2-16T

MITSUBISHI AJ65VBTCE2-16T Manual And Instructions
AJ65VBTCE2-16T datasheetPDF datasheet

MITSUBISHI AJ65VBTCE2-16T Product information and technical parameters:
Brand: MITSUBISHI
Name: Sensor connector type transistor output module
Model: AJ65VBTCE2-16T
Output type: transistor output, drain type.
Output points: 16 points.
OFF leakage current: 0.1mA.
Output protection function.
Rated load voltage / current: DC24V/DC24V/0.1A.
External connection: 2 wire.
Sensor connector type (E-CON type).
Using industry standard E-CON type.
Simple wiring through sensor connector.
When installing the module can choose to use the DIN guide rail or screw mounting.
3 wire sensor input.

Input type: DC input, negative public end.
Input points: 8 points.
Enter the response time: 1.5ms the following.
Rated input voltage / current: DC24V/5mA.
Output form: transistor output, source.
Output points: 8 points.
OFF leakage current: 0.1mA.
Output protection function.
Rated load voltage / current: DC24V/DC24V/0 MITSUBISHI AJ65VBTCE2-16T. 1A.
External connection: 3 line /2 line type.
Sensor connector type (E-CON type) AJ65VBTCE2-16T
Using industry standard E-CON type.
Simple wiring through sensor connector.
When installing the module can choose to use the DIN guide rail or screw mounting.
3 wire sensor input. Output type: transistor output, drain type.
Output points: 16 points.
OFF leakage current: 0.1mA.
Output protection function: No MITSUBISHI AJ65VBTCE2-16T.
Rated load voltage / current: DC12V/DC24V/0.5mA.
External connection: 1 wire.
Type of input and output terminal.
Using 2 pieces of structure of the terminal units, maintenance can be maintained in the same line under the condition of the replacement module. Screw, 2 piece type terminal
Thermocouple Input module.
Number of channels: 8 channels.
Number of stations: 4 stops.
Station type: remote equipment station MITSUBISHI AJ65VBTCE2-16T.
MITSUBISHI PLC online debugging.
On-line debugging is the process that will through the simulation debugging to further carry on the on-line unification to adjust.
On-line debugging process should be step by step,
From MITSUBISHI PLC only connected to the input device, and then connect the output device, and then connect to the actual load and so on and so on step by step.
If you do not meet the requirements, the hardware and procedures for adjustment.
Usually only need to modify the part of the program can be.
MITSUBISHI PLC hardware implementation
Hardware implementation is mainly for the control cabinet and other hardware design and field construction.
Design control cabinet and the operating table and other parts of the eelectrical wiring diagram and wiring diagram AJ65VBTCE2-16T.
Electrical interconnection diagram of each part of the design system.
According to the construction drawings of the site wiring, and carry out a detailed inspection.
Because the program deesign and hardware implementation can be carried out at the same time,
So the design cycle of the MITSUBISHI PLC control system can be greatly reduced AJ65VBTCE2-16T.