Input and output points: 14 points.
Power supply: AC100-240V.
Input points: 8 points.
Output points: 6 points.
Output form: relay output.
Power consumption: 19W.
Weight: 0.3KG.
Outline dimension: 60x90x75mm.
A new application model.
FX3SA is a basic model on the basis of the basic performance of FX1S above the expansion of the expansion of the new model.
FX3SA is applicable to all kinds of fields of small scale equipment which need to simulate the quantity and function of MODBUS and Ethernet
HF-SP152K
Basic models suitable for small scale control.
Compact but powerful,
At the same time, the analog quantity and communication function, etc.. Motor series: super low inertia, medium power.
Rated output power: 1.0kw.
Rated speed: 3000r/min.
Whether to take the brake: No.
Shaft keyway: (open slot).
Protection level: IP65 (IP67).
Features: ultra low inertia is suitable for high frequency operation.
Application example: ultra high frequency transmission machinery.
High resolution encoder 131072p/rev (17 bit).
The encoder with high resolution ensures excellent performance and stability at low speed.
All motor dimensions are the same as before and all are compatible with the wiring.
Input voltage range: AC100 ~ 120V.
Output voltage: DC24V.
Output current: 0.6A.
Relay output interface circuit of PLC
Working process: when the internal circuit output digital signal 1,
There is a current flowing through, the relay coil has a current, and then the normally open contact is closed,
Provide load current and voltage.
When the internal circuit outputs a digital signal 0, there is no current flowing through it,
The relay coil does not have a current, and the normally open contact is broken off,
A current or voltage that is disconnected from the load.
It is through the output interface circuit to the internal digital circuit into a signal to make the load action or not action.
I/O points is an important indicator of PLC.
Reasonable selection of I/O points can not only satisfy the control requirements of the system,
And the total investment of the system is the lowest.
The input and output points and types of PLC should be determined according to the analog quantity and switch quantity of the controlled object,
Generally an input / output element to take up an input / output point.
Taking into account the future adjustment and expansion,
In general should be estimated on the total number of points plus the amount of spare 20%~30%.
The following describes the centralized control system I/O points of the estimate.
HF-SP152K Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=HF-SP152K&select=5