Servo motor series: low inertia, medium / high power.
Rated output: 0.75kw.
Rated speed: 3000r/min.
Electromagnetic brake: No.
Shaft end specification: Standard (straight axis).
Voltage: 400V level.
Features: low inertia for high speed / acceleration and deceleration operation occasions.
IP level: IP67.
Application example:
1, food processing machinery.
2, printing machine.
3, injection molding machine (11KW, 15KW)
MR-J3-60B4
4, large press machine (11KW, 15KW).
The protection level of the HF-SP/HF-JP series servo motor is IP67 (except the shaft part).
Low inertia of the power servo motor (0.5kW ~ 9kW), the maximum speed: 6000r/min (rated speed: 3000r/min),
Suitable for high frequency positioning and acceleration / deceleration operations, especially for food processing machines and printing machines.
Low inertia, high power, no cooling fan servo motor (11kW and 15kW), maximum speed: 3000r/min (rated speed: 1500r/min).
The motor structure is more compact due to the adoption of the non cooling fan design, and the connection is reduced by using the power source connector.
(compared with the HF-LP series servo motor with the same power, the volume is reduced by about 46%, and the weight is reduced by about 34%,
Suitable for high frequency positioning and acceleration / deceleration operations, especially for injection molding machines and large presses.
HF-JP703 (4) /903 (4) maximum speed: 5000r/min. Safety grade (SIL): SIL 3 (IEC 61508).
Performance level (PL): e PL (13849-1 EN/ISO).
Operation control mode: stored procedures repeated operation.
Program capacity: 160K (security program: 40K).
Program memory: 640K.
Soft element / tag memory: 1710K.
Data memory: 10M.
Integrate security functions into the control system.
Can be used in the previous iQ-R MELSEC series module as a general control purposes,
Use on the same substrate, it can be used to construct a hybrid system with general control and safety control.
Moreover, IE Field CC-Link network can be integrated with general communication and secure communication,
Ethernet cable can also be used in secure communication,
No need to use a dedicated cable, etc..
In line with the international safety standards for the safety of CPU can be controlled at the same time the general system and safety system.
Available through IE Field CC-Link network,
Connect the safety switch and safety light curtain system used to secure CPU,
System for the construction of a general control and safety control system.
In addition, through the use of intuitive engineering software Works3 GX,
Focus on general control and safety control programming.
MR-J3-60B4 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=MR-J3-60B4&select=5