Home >> Price >> MITSUBISHI >> MR-J3-11KB4-RJ006 Market price | MR-J3-11KB4-RJ006 Introduction
Brand sort

MITSUBISHI MR-J3-11KB4-RJ006 Market price | MR-J3-11KB4-RJ006 Introduction

Country: JAPAN
Name: Full closed loop control driver
Price: 0
MITSUBISHI MR-J3-11KB4-RJ006
Input: 2 channels.
50kpps.
Counter input signal: DC5/12/24V.
External input: DC5/12/24V.
Uniform output: Transistor (drain type).
Used to replace the A series of large modules "AD61".
40 pin connector.
Support high resolution devices. Pulse input and high speed counter module product group satisfying high speed and high precision control application.
High speed counter module for counting high-speed pulse train MR-J3-11KB4-RJ006
Can be used in combination with the external encoder for positioning and other control.
The maximum count rate can be switched, and the low frequency pulse is counted from the high speed pulse to the rising edge / falling edge.
Each 1 channel is equipped with 2 points of external uniform output.
Can be selected according to the use of "consistent output function", "continuous comparison function", to achieve high-speed control of external equipment. (QD64D2)
Provides a variety of functions, such as the same output test function (using a continuous comparison function), the default function, the latch counter function,
In order to meet the needs of various applications. (QD64D2)
The maximum count rate of the input pulse can be up to 8Mpps (differential input, 2 phase, 4 double frequency).
Can be in the semiconductor, liquid crystal manufacturing and other high position accuracy requirements of the equipment,
Perform accurate position tracking using high resolution encoders. (QD65PD2)Power: 0.4kw.
Purpose: high frequency braking resistor.
The use rate of the built-in regenerative brake of the transducer can be promoted.
When using the FR-ABR type brake resistor, the short circuit piece between the terminal PR-PX is removed. Does not remove the short circuit chip will lead to overheating of the brake resistor.
The utilization rate of the regenerative braking should be less than the allowable brake use rate in the above table.
With the operating frequency of the brake resistor to reach 300 degrees C or higher, it is necessary to take protective measures and cooling.
MYS type resistor can be used. But please pay attention to the allowable brake use rate.
Do not remove the terminal P/+ and P1 between the short circuit chip, in addition to connecting the DC reactor.
The installation of thermal relay, to avoid overheating and burn the braking resistor.
MR-J3-11KB4-RJ006 Operation manual / Instructions / Catalog download link: /searchDownload.html?Search=MR-J3-11KB4-RJ006&select=5


...more relevant model market price >>>>