Industrial level switch hub.
NZ2EHF-T8 supports 10Mbps/100Mbps transfer rate.
With MDI/MDI-X Auto function, automatic negotiation function, etc..
The use of automatic power regulation function, can make up to a reduction of about 80%*2.
Do not use the cooling fan, but can be in a larger ambient temperature range (0 ~ 50 degrees C) normal operation NZ2EHG-T8 datasheet PDF catalog NZ2EHG-T8 PDF datasheet
NZ2EHG-T8
By using simple and easy loading and unloading DIN guide rail fixing mechanism, all kinds of installation can be easily carried out. Type: 18 point terminal.
Input / output mode: analog voltage and current output.
Number of channels: 4 channels.
No need to extend or change the network wiring to increase the number of analog points.
The conversion speed of the analog input module can be selected from 100 mu s/ channel, 400 mu s/ channel and 1ms/ channel NZ2EHG-T8 datasheet PDF catalog NZ2EHG-T8 PDF datasheet. (switching speed switching function)
The conversion speed of the analog output module is 100 mu s/ channel.
Can be connected to the analog input / output module (NZ2GF2BN-60AD4, NZ2GF2BN-60DA4) after the use of.
IE CC-Link field network remote equipment station. According to the equipment, more easily distributed input and output devices NZ2EHG-T8 datasheet PDF catalog NZ2EHG-T8 PDF datasheet.
Can be connected to the expansion module, more convenient to expand the input and output points.
Support synchronous communication (using with simple motion control module).
According to the simple motion control module of the network (Master) control cycle of the implementation of the control cycle and its synchronization,
Implementation of multiple simultaneous action from the station. Capacity: 1MB.Type: sensor connector (e-CON).
Input form: DC input, negative public end.
Input points: 16 points.
Rated input voltage / current: DC24V (4mA).
External connection: 3 wire.
IE CC-Link field network module type remote unit.
Select input response time from 0ms/0.2ms/1ms/1.5ms/5ms/10ms/20ms/70ms.
High speed input and output control of single module can be realized by using first order logic function.
IE CC-Link field network remote equipment station. According to the equipment, more easily distributed input and output devices.
Can be connected to the expansion module, more cconvenient to expand the input and output points NZ2EHG-T8 datasheet PDF catalog NZ2EHG-T8 PDF datasheet.
Support synchronous communication (using with simple motion control module).
According to the simple motion control module of the network (Mastter) control cycle of the implementation of the control cycle and its synchronization,
Implementation of multiple simultaneous action from the station NZ2EHG-T8 datasheet PDF catalog NZ2EHG-T8 PDF datasheet.