MELSECNET/B.
Twisted pair bus. A1SG60 is an empty cover that is used to plug in the unused I/O slot on the main board or on the extended board.
A1SG60 is a reserved dummy module I/O point to PLC extended I/O system.
With the switch on the module can be set to retain the I/O point,
Can set 16 points, 32 points, 48 points and 64 points AJ65SBTB32-16DT2 datasheet PDF catalog AJ65SBTB32-16DT2 PDF datasheet
AJ65SBTB32-16DT2 Cable length: 3 meters.
For GOT and parallel printer connection. RS-232 2 channel.
Transmission speed: 2 channels.
At the same time the use of 115.2kbps may.
Input status and input information input from the input interface,
CPU will be stored in the working data memory or in the input image register.
And then combine the data and the program with CPU.
The result is stored in the output image register or the working data memory,
And then output to the output interface, control the external drive AJ65SBTB32-16DT2 datasheet PDF catalog AJ65SBTB32-16DT2 PDF datasheet.
Semiconductor circuit with memory function.
System program memory and user memory.
System program memory for storing system program,
Including management procedures, monitoring procedures, as well as the user program to do the compiler to compile the process of interpretation AJ65SBTB32-16DT2 datasheet PDF catalog AJ65SBTB32-16DT2 PDF datasheet.
Read only memory. Manufacturers use, content can not be changed, power does not disappear. Output type: transistor output, source.
Output points: 16 points.
OFF leakage current: 0.30mA.
Output protection function.
Rated load voltage / current: DC12V/DC24V/0.1A.
External connection: 2 wire.
Waterproof connector type.
Strong waterproof type of IP67 protection grade.
No need to stop the system can be replaced module.
Without the use of tools can be a simple connection, save time.
Terminal resistor built-in.
Can be installed along the 6 direction.
Hardware simulation method is to use a number of hardware equipment to simulate the generation of the signal,
The signals are connected to the input end of the PLC system in a hard wired way, and the timeliness is strong.
Software simulation methood is in the MITSUBISHI PLC in the preparation of a set of simulation program,
The simulation provides the field signal, which is simple and easy to operate, but it is not easy too guarantee the timeliness AJ65SBTB32-16DT2 datasheet PDF catalog AJ65SBTB32-16DT2 PDF datasheet AJ65SBTB32-16DT2 datasheet PDF catalog AJ65SBTB32-16DT2 PDF datasheet.
Simulation of the process of debugging, debugging method can be used to segment, and the monitoring function of programmer.