352此ID下载地址不存在3--/downloadfile/261-MELSEC-QL-MELSEC-Communication-Protocol-Reference.pdf MITSUBISHI Q172CPU Communication Protocal Manual Q172CPU Reference Manual - MITSUBISHI
MITSUBISHI
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI Q172CPU Communication Protocal Manual Q172CPU Reference Manual

MITSUBISHI Q172CPU Communication Protocal Manual Q172CPU Reference Manual

Brand: MITSUBISHI
Product model: Q172CPU
Name: PLC
Sort: Reference Manual (Communication Protocal)
File language: English
File size: 0.00MB
Express PCI bus.
Support Japanese, English OS.
Master / local station sharing.
Support Ver.2 CC-Link version.
Province distribution network module in cabinet and device.
Link to connect the 64 stations when the fastest scanning time for 1.2ms (rate 2.5Mbps).
According to the transmission distance, the transmission rate is selected from 2 Q172CPU Communication Protocal Manual Q172CPU Reference Manual Q172CPU 5Mbps, 625kbps and 156kbps.
CC-Link/LT from the station does not need any parameter settings.
Only need to set up the transmission speed in the master module, you can use the remote I/O.
I/O control in the first class of open field network module.
CC-Link based on reliable field bus technology,
Able to transmit large number of bits data (such as ON/OFF information) and word data (such as analog information) Q172CPU Communication Protocal Manual Q172CPU Reference Manual.
Consistency of CC-Link to maintain loop transmission,
And the cycle of transmission and information (instantaneous transmission) communication separately, so as to ensure the timeliness of.
Even if the information reaches saturation, it will not affect the link scan time.
Make the mixed data environment intelligent, to achieve a new manufacturing system IE CC-Link field network module Q172CPU Communication Protocal Manual Q172CPU Reference Manual.
Using Ethernet cables and connectors available on the market to reduce costs.
High speed communication capable of communicating with 1Gbps.
Improve the communication response, significantly shorten the cycle time.
Improve the performance of cycle data update. Reduces the transmission delay time and the application of the synchronization waiting time.
Data can be read or written to other station programmable controller.
Status of IE CC-Link field network can be confirmed by Works2 GX.
Can be in the Works2 GX up and down the abnormal position, the cause of the exception, the event record,
So it can reduce the time of abnormal to resume normal operation.Program capacity: 8K step.
Input / output points: 256 points.
Number of input and output elements: 2048.
Power +5 tank bottom plate of the CPU.
Continue to go beyond, to climb the peak of Q series.
Strengthen security function.
Can be set up to 32 characters of the file password.
In addition to the English letters, numbers, but also the use of special characters,
To further enhance the security of the password.
In addition, only pre registered devicees are allowed to access CPU,
To intercept unauthorized access to unauthorized users Q172CPU Communication Protocal Manual Q172CPU Reference Manual.
Therefore, it is important to prevent the outflow of important program assets and protect intellectuual property rights Q172CPU Communication Protocal Manual Q172CPU Reference Manual.
CPU module expansion standard RAM (max 8MB).
Can be used with the SD memory card at the same time.
Continuous access file register.
Related products
MITSUBISHI
Process CPU
Q12PRHCPU
MITSUBISHI Process CPU Q12PRHCPU
Program capacity: 124 K step. Input / output
MITSUBISHI
Programmable logic controller CPU
R08ENCPU
MITSUBISHI Programmable logic controller CPU R08ENCPU
Operation control mode: stored procedure repe
MITSUBISHI
Motion CPU module
Q173DCPU
MITSUBISHI Motion CPU module Q173DCPU
Control axis: maximum 32 axes. Manual pulse g