Multimode fiber optic cable.
Double circuit.
Controller network (control station / common station).
Decentralized control of large scale controller,
IE CC-Link controller network module connected with various field network.
Effectively using Ethernet cable and connector on the market, can reduce the cost Q03UDECPU MELSAP-L Manual Q03UDECPU Programming Manual.
The performance of the cycle data update is improved
Q03UDECPU
The transmission delay time is shortened, and the synchronous waiting time of the application can be shortened.
On the same network to achieve the 256KB network shared memory (cycle data).
No need to distinguish the network can handle large capacity data.
QJ71GP21S-SX, CC-Link can be used as the control station of IE QJ71GP21-SX controller network, common station Q03UDECPU MELSAP-L Manual Q03UDECPU Programming Manual. Master station.
Province distribution network module in cabinet and device.
Link to connect the 64 stations when the fastest scanning time for 1.2ms (rate 2.5Mbps).
According to the transmission distance, the transmission rate is selected from 2.5Mbps, 625kbps and 156kbps.
CC-Link/LT from the station does not need any parameter settings.
Only need to set up the transmission speed in the master module, you can use the remote I/O Q03UDECPU MELSAP-L Manual Q03UDECPU Programming Manual.
QJ61CL12 can be used as the main station of CC-Link/LT.Input voltage range: AC100-120V/AC200-240V.
Output voltage: DC5V.
Output power: 8.5A.
Simplified program debugging
Can use the software with the implementation of the conditions of the test function, any step in the program,
Changes the value of the soft component to a user specified value.
In the past, when debugging the specific loop process, the need to add a set of soft components of the program,
At present, through the use of the function, no need to change the program, you can make a specific loop program segment execution action.
Therefore, do not need to change the program separately in order to debug, debugging operation is more simple.
Auto backup key data
Save the program and parameter files automatically to the program memory (ROM Flash) without using the backup battery,
To prevent the loss of the program and the parameters due to forgetting to replace the battery.
In addition, the soft component data and other important data can be backed up to the standard ROM,
In order to avoid during the long holiday and oother planned downtime,
The data is lost due to battery depletion Q03UDECPU MELSAP-L Manual Q03UDECPU Programming Manual.
The next time the power is turned on, the backup data will be automatically restored.
Through the expansion of soft components,, more convenient to create the program Q03UDECPU MELSAP-L Manual Q03UDECPU Programming Manual.
M soft components and B soft components can be expanded to 60K points, making the program easier to understand.