MITSUBISHI Q03UDECPU Common Instruction 1/2 Manual Q03UDECPU Programming Manual

Brand: MITSUBISHI
Product model: Q03UDECPU
Name: PLC
Sort: Programming Manual (Common Instruction 1/2)
File language: English
File size: 0.00MB
Three-phase 3 wire type.
Measuring circuit number: 4 circuits.
Measurement items: power consumption (consumption, regeneration), current, voltage, power, power factor, etc..
Power measurement module product group capable of simply measuring various energy information.
With only one module can be used to measure and power consumption (consumption and regeneration), reactive power, current, voltage, power, power factor and frequency of all kinds of detailed information Q03UDECPU Common Instruction 1/2 Manual Q03UDECPU Programming Manual Q03UDECPU
No ladder program can continue to monitor the minimum and maximum values, can also perform 2 types of upper / lower limit alarm.
Only in the ON state can be used to measure the output of the output device.
Therefore, the amount of electricity and the quantity of electricity in the unit of the beat can be obtained during the operation of the equipment Q03UDECPU Common Instruction 1/2 Manual Q03UDECPU Programming Manual.
3 phase 3 wire products can be used to measure up to 4 circuits in one slot,
3 phase 4 wire products can be used to measure up to 3 circuits,
So the electrical energy measurement can be carried out in a small space by the multi circuit products.
For example, a module can be used to measure other loads from the control panel trunk Q03UDECPU Common Instruction 1/2 Manual Q03UDECPU Programming Manual.
In addition, Works2 GX (version 1.90U and higher) can be used to easily set parameters.Input: 4 channels.
Thermocouple (K, J, T, B, S, E, R, N, U, L, PLlI, W5Re/W26Re,,).
Heater disconnection detection function.
Sampling period: 0.5s/4 channel.
18 point terminal table x2.
Peak current suppression.
Can prevent the simultaneous opening of the output to control the peak current, which is helpful for saving energy and reducing the operation cost.
Heating function at the same time.
The multiple loop can reach the set value at the same time to carry out the uniform temperature control,
Helps to prevent no-load and effective energy saving and reduce operating costs.
Automatic adjustment function.
The PID constant can be adjusted automatically in the control process.
Automatic adjustment of cost (time, material and electrical energy) can be reduced.
Can be flexible in various settings, to achieve the best temperature control of the temperature control module.
Equipment for high temperature control stability of extrusion molding machine,
The temperature regulating module has the functiion of preventing overheating and preventing over cooling Q03UDECPU Common Instruction 1/2 Manual Q03UDECPU Programming Manual.
According to the control object device, select the standard control (heating or cooling) or the heating and cooling contrrol (heating and cooling) mode Q03UDECPU Common Instruction 1/2 Manual Q03UDECPU Programming Manual.
In addition, the mixed control mode (combined with the standard control and heating - cooling control) can be selected.
Related products
MITSUBISHI
With Ethernet CPU
Q03UDECPU
MITSUBISHI With Ethernet CPU Q03UDECPU
Input / output points: 4096 points. Numer of
MITSUBISHI
General high speed CPU
Q03UDVCPU
MITSUBISHI General high speed CPU Q03UDVCPU
Input / output points: 4096 points. Input / o
MITSUBISHI
General purpose CPU
Q03UDCPU
MITSUBISHI General purpose CPU Q03UDCPU
Input / output points: 4096 points. Numer of