MITSUBISHI Q02UCPU PID Control Instructions Manual Q02UCPU Programming Manual

Brand: MITSUBISHI
Product model: Q02UCPU
Name: PLC
Sort: Programming Manual (PID Control Instructions)
File language: English
File size: 0.00MB
Input / output points: 4096 points.
You can use the CF card.
Version OS:VxWorks 5.4.
Simply insert the SD memory card, you can automatically record.
Simply insert the SD in the CPU to save the record setting file, you can automatically start recording.
Even when remote data collection is required,
After receiving a record setting file by mail and copy it to the SD memory card,
Can immediately start recording Q02UCPU PID Control Instructions Manual Q02UCPU Programming Manual Q02UCPU
Automatically transfer the record file to the FTP server
Simply by recording the configuration tool to carry out a simple setup,
A data record file stored on the SD memory card can be sent to the FTP server.
Because the record server can handle multiple files, it can reduce the task of management and maintenance Q02UCPU PID Control Instructions Manual Q02UCPU Programming Manual.
When a failure occurs, it can quickly respond to.
Simply extract the data associated with the problem, do not have to spend a lot of time to filter a large number of diagnostic data,
So it can quickly determine the cause of the failure, and make the solution.GI-62.5/125 optical cable.
Double ring.
PLC to PLC network (control station / common station) / remote I/O net (remote master station) Q02UCPU PID Control Instructions Manual Q02UCPU Programming Manual. 4 channel.
Input: DCO~20mA DC-10~10V.
Output (resolution): 0~32000; -32000~32000; 0~64000; -64000~64000.
Conversion speed: 10ms/4 channel.
18 point terminal station.
Isolation between channels.
The possibility of expanding control with intelligent function.
At the same time, the channel isolation analog module realizes high isolation voltage,
Further improve the accuracy of the benchmark.
Provide support for process control using a general purpose programmable controller.
Flow meter, pressure meter, other sensors can be directly connected to analog input,
Control valve can also be directly connected to analog output.
Hardware and installation costs have been greatly reduced due to the need for an extternal isolation amplifier Q02UCPU PID Control Instructions Manual Q02UCPU Programming Manual.
High insulation strength.
Can isolate electrical interference, such as current and noise, etc..
Standard analog input module.
Isolated analog input modulee Q02UCPU PID Control Instructions Manual Q02UCPU Programming Manual.
No external isolation amplifier required.
Without the use of inter channel isolation analog modules.
Using the inter channel isolation analog module.
Related products
MITSUBISHI
CPU unit
A2UCPU
MITSUBISHI CPU unit A2UCPU
Input and output points: 512 points. Input /
MITSUBISHI
CPU unit
A1SCPU
MITSUBISHI CPU unit A1SCPU
Program memory capacity: 8k. Input / output p
MITSUBISHI
General purpose CPU
Q20UDHCPU
MITSUBISHI General purpose CPU Q20UDHCPU
Specification model: Q20UDHCPU. Input / outpu
MITSUBISHI
Process CPU
Q25PRHCPU
MITSUBISHI Process CPU Q25PRHCPU
Program capacity: 252 K step. Input / output