SRAM memory card.
RAM capacity: 512KB. Input / output points: 4096 points.
You can use the CF card.
Version OS:VxWorks 6.4.
Simply insert the SD memory card, you can automatically record.
Simply insert the SD in the CPU to save the record setting file, you can automatically start recording.
Even when remote data collection is required,
After receiving a record setting file by mail and copy it to the SD memory card,
Can immediately start recording Q02HCPU Application Functions Manual Q02HCPU Programming Manual
Q02HCPU
Automatically transfer the record file to the FTP server
Simply by recording the configuration tool to carry out a simple setup,
A data record file stored on the SD memory card can be sent to the FTP server.
Because the record server can handle multiple files, it can reduce the task of management and maintenance Q02HCPU Application Functions Manual Q02HCPU Programming Manual.
When a failure occurs, it can quickly respond to.
Simply extract the data associated with the problem, do not have to spend a lot of time to filter a large number of diagnostic data,
So it can quickly determine the cause of the failure, and make the solution.Upgraded version.
Control axis: maximum 32 axes.
Manual pulse generator operation function: can use 3 sets of manual pulse generator Q02HCPU Application Functions Manual Q02HCPU Programming Manual.
Synchronous encoder operation function: can use 12 synchronous encoder.
Peripheral I/F: by CPU PLC.
High speed motion control system based on multi CPU architecture.
Multi CPU system based on Q series PLC.
Flexible selection of CPU PLC and motion CPU according to different applications.
In the construction of multi CPU system, can have up to 4 sets of CPU.
When 3 Q173DCPU is used, the maximum 96 axes can be controlled.Input points: 8 points (dual input), 16 points (single input).
Isolation mode: photoelectric coupling.
Rated input voltage: DC24V.
Output points: 4 points (select the source type + drain type), 2 points (when selecting the source type + source).
Isolation mode: photoelectric coupling.
Rated input voltage: DC24V.
Security PLC (secure programmable system) refers to the self or external components or the implementation of the failure of the agency,
Can still respond to and promptly cut off the output of the programmable system.
Different from ordinary PLC, security PLC not only can provide the function of ordinary PLC,
Safe control function can be realized,
Meet the requirements of the ISO 13849-1 EN and IEC 61508 control system safety related component standards.
PLC security market mainstream has oilz (Pilz) PSS 3000, PSS 4000,
PSS 4000 in addition to the security process can also be processed outside the standard control procedures.
All the commponents in the security PLC adopt the redundancy structure,
Two processor processing for cross detection,
The processing results of each processor are stored in their respective memoryy,
Output is only when the processing result is in full agreement,
If any inconsistency occurs during the process, the system is immediately shut down Q02HCPU Application Functions Manual Q02HCPU Programming Manual Q02HCPU Application Functions Manual Q02HCPU Programming Manual.