MITSUBISHI A2CCPU Dedicated Instructions Manual A2CCPU Programming Manual

Brand: MITSUBISHI
Product model: A2CCPU
Name: PLC
Sort: Programming Manual (Dedicated Instructions)
File language: English
File size: 17.11MB
Input points: 16 points.
Input voltage and current: 3/7mA DC12/24V.
Input response time: 10ms.
16 point /1 a public side.
Positive pole sharing.
Output points: 12 points.
Output voltage: DC24V/AC240V, 2A/1 point, 5A/1 common end.
Output response time: 12ms.
Output type: relay output.
8 point /1 a public end, 3 point /1 a public end A2CCPU Dedicated Instructions Manual A2CCPU Programming Manual.
Independent contact A2CCPU
36 point terminal station.
Control solenoid valve required I/O points by the action principle of the solenoid valve can be known,
A single coil solenoid valve with PLC control to 2 input and 1 output,
A double coil solenoid valve requires 3 inputs and 2 outputs,
A button needs an input; a light sensitive switch needs 4 or 2 inputs,
A signal lamp needs 1 output, band switch,
Several bands are required for several inputs,
In general, a variety of position switches are required to take up 2 input points A2CCPU Dedicated Instructions Manual A2CCPU Programming Manual.
MITSUBISHI PLC is the main product in the production of MITSUBISHI motor in Dalian.
It uses a kind of programmable memory for its internal storage procedures,
Execute logic operation, sequence control, timing, counting and arithmetic operations, user oriented instruction,
And through digital or analog input / output control of various types of machinery or production process A2CCPU Dedicated Instructions Manual A2CCPU Programming Manual.
The number of I/O thyristor DC motor control required tube DC motor speed control system is the main form of DC speed regulation,
The thyristor rectifier unit is used to supply power to the DC motor.
PLC control of the DC drive system, the input of the PLC in addition to the main signal outside the signal,
We need to consider the switching signal, the fault signal transmission device, brake signal and fan fault signal.
The ooutput of the PLC mainly consider the speed command signal positive 1~3 level, 1~3 level, allowing reverse switching signal and brake open signal etc A2CCPU Dedicated Instructions Manual A2CCPU Programming Manual. .
In general, a reversible DC drivee system controlled by PLC is approximately 12 input points and 8 output points,
An irreversible DC drive system requires 9 inputs and 6 output points A2CCPU Dedicated Instructions Manual A2CCPU Programming Manual.
Related products
MITSUBISHI
CPU unit
A2CCPUC24-PRF
MITSUBISHI CPU unit A2CCPUC24-PRF
Input and output points: 512 points. Input /
MITSUBISHI
With Ethernet CPU
Q03UDECPU
MITSUBISHI With Ethernet CPU Q03UDECPU
Input / output points: 4096 points. Numer of
MITSUBISHI
With Ethernet CPU
Q13UDEHCPU
MITSUBISHI With Ethernet CPU Q13UDEHCPU
Input / output points: 4096 points. Numer of