Input: 2 channels.
500/200/100/10kpps.
Counter input signal: DC5/12/24V.
External input: DC5/12/24V.
Uniform output: Transistor (drain type).
DC12/24V.
0.5A/ point.
2A common end.
40 pin connector. Compact flash memory card.
Capacity: 2GB bytes. Input: 4 channels.
Thermocouple (K, J, T, B, S, E, R, N, U, L, PLlI, W5Re/W26Re,,) Q01CPU Common Instructions Manual Q01CPU Strctured Programming Manual.
Heater disconnection detection function
Q01CPU
Sampling period: 0.5s/4 channel.
18 point terminal table x2.
Can be flexible in various settings, to achieve the best temperature control of the temperature control module.
Equipment for high temperature control stability of extrusion molding machine,
The temperature regulating module has the function of preventing overheating and preventing over cooling Q01CPU Common Instructions Manual Q01CPU Strctured Programming Manual.
According to the control object device, select the standard control (heating or cooling) or the heating and cooling control (heating and cooling) mode.
In addition, the mixed control mode (combined with the standard control and heating - cooling control) can be selected.
Peak current suppression.
Can prevent the simultaneous opening of the output to control the peak current, which is helpful for saving energy and reducing the operation cost Q01CPU Common Instructions Manual Q01CPU Strctured Programming Manual.
Heating function at the same time.
The multiple loop can reach the set value at the same time to carry out the uniform temperature control,
Helps to prevent no-load and effective energy saving and reduce operating costs.
Automatic adjustment function.
The PID constant can be adjusted automatically in the control process.
Automatic adjustment of cost (time, material and electrical energy) can be reduced. Module connector 1Ch.
1ch RS-232.
The possibility of expanding control with intelligent function.
Providing a variety of analog modules, is the ideal choice for process control applications.
Can also meet the needs of high speed, high precision control.
Most suitable analog modules for high speed conversion control.
Can provide a variety of analog and digital analog conversion module products.
These modules have a variety of functions, in the connection of equipment, to achieve the greatest flexibility.
Can meet the inverter control, such as high-speed conversion needs.
Easy connection programming tool via ethernet.
Programming tools (Works2 GX, Developer GX) and CPU direct connection (1 to 1),
No need to carry out the IP address settings Q01CPU Common Instructions Manual Q01CPU Strctured Programming Manual. And there is no need to select the cable, the straight line and the cross line can be used.
Therefore, this connection method annd the use of USB, can easily communicate with the CPU,
Even the operators are not familiar with the network settings can easily establish a connection Q01CPU Common Instructions Manual Q01CPU Strctured Programming Manual.