MITSUBISHI
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI Q00UCPU PID Control Instructions Manual Q00UCPU Programming Manual

MITSUBISHI Q00UCPU PID Control Instructions Manual Q00UCPU Programming Manual

Brand: MITSUBISHI
Product model: Q00UCPU
Name: CPU
Sort: Programming Manual (PID Control Instructions)
File language: English
File size: 1.90MB
FL-net (OPCN-2) Ver.2.00 interface.
10BASE5/10BASE-T use.
Real time transmission control data, to improve the production efficiency and the value of the equipment to provide support for the high-speed data communication module.
The high accuracy data that can be synchronized with the sequential scanning to the user program on the PC can be transmitted through the Ethernet Q00UCPU PID Control Instructions Manual Q00UCPU Programming Manual Q00UCPU
Realize the previous communication method can not achieve the detailed control of data transmission,
Real time data analysis using user applications,
In order to provide support for improving production efficiency and equipment value.
Easy connection programming tool via ethernet.
Programming tools (Works2 GX, Developer GX) and CPU direct connection (1 to 1),
No need to carry out the IP address settings Q00UCPU PID Control Instructions Manual Q00UCPU Programming Manual . And there is no need to select the cable, the straight line and the cross line can be used.
Therefore, this connection method and the use of USB, can easily communicate with the CPU,
Even the operators are not familiar with the network settings can easily establish a connection.Output: 6 channels.
Input (resolution): 0~4000; -4000~4000; 0~12000; -12000~12000; -16000~16000 Q00UCPU PID Control Instructions Manual Q00UCPU Programming Manual .
Output: DC-12V~12V; 0~22mA.
Conversion speed: 6ms/ channel.
40 pin connector.
Isolation between channels.
The possibility of expanding control with intelligent function.
At the same time, the channel isolation analog module realizes high isolation voltage,
Further improve the accuracy of the benchmark.
Provide support for process control using a general purpose programmable controller.
Flow meter, pressure meter, other sensors can be directly connected to analog input,
Control valve can also be directly connected to analog output.
Hardware and installation costs have been greatly reduced due to the need for an exterrnal isolation amplifier Q00UCPU PID Control Instructions Manual Q00UCPU Programming Manual .
High insulation strength.
Can isolate electrical interference, such as current and noise, etc..
Standard analog input module.
Isolated analog input module. Q00UCPU PID Control Instructions Manual Q00UCPU Programming Manual .
No external isolation amplifier required.
Without the use of inter channel isolation analog modules.
Using the inter channel isolation analog module.
Related products
MITSUBISHI
CPU unit
A0J2CPU
MITSUBISHI CPU unit A0J2CPU
Input and output points: 480 points. Program
MITSUBISHI
CPU unit
A1NCPU
MITSUBISHI CPU unit A1NCPU
Input and output points: 256 points. Input /
MITSUBISHI
CPU component
A1SJHCPU
MITSUBISHI CPU component A1SJHCPU
I/O control method: refresh mode or direct mo