1180此ID下载地址不存在3--/downloadfile/32-MELSEC-QL-Serial-Communicationxxd-(Application).pdf MITSUBISHI Q00JCPU-E Application Manual Q00JCPU-E User's Manual - MITSUBISHI
MITSUBISHI
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI Q00JCPU-E Application Manual Q00JCPU-E User's Manual

MITSUBISHI Q00JCPU-E Application Manual Q00JCPU-E User's Manual

Brand: MITSUBISHI
Product model: Q00JCPU-E
Name: PLC
Sort: User's Manual (Application)
File language: English
File size: 0.00MB
Input points: 8 points (dual input), 16 points (single input).
Isolation mode: photoelectric coupling.
Rated input voltage: DC24V.
Security PLC (secure programmable system) refers to the self or external components or the implementation of the failure of the agency,
Can still respond to and promptly cut off the output of the programmable system Q00JCPU-E Application Manual Q00JCPU-E User's Manual.
Different from ordinary PLC, security PLC not only can provide the function of ordinary PLC,
Safe control function can be realized,
Meet the requirements of the ISO 13849-1 EN and IEC 61508 control system safety related component standards Q00JCPU-E
PLC security market mainstream has oilz (Pilz) PSS 3000, PSS 4000,
PSS 4000 in addition to the security process can also be processed outside the standard control procedures Q00JCPU-E Application Manual Q00JCPU-E User's Manual.
All the components in the security PLC adopt the redundancy structure,
Two processor processing for cross detection,
The processing results of each processor are stored in their respective memory,
Output is only when the processing result is in full agreement,
If any inconsistency occurs during the process, the system is immediately shut down Q00JCPU-E Application Manual Q00JCPU-E User's Manual. Input: 4 channels.
Thermocouple (K, J, T, B, S, E, R, N, U, L, PLlI, W5Re/W26Re,,).
No heater disconnection detection function.
Sampling period: 0.5s/4 channel.
18 point terminal station.
Can be flexible in various settings, to achieve the best temperature control of the temperature control module.
Equipment for high temperature control stability of extrusion molding machine,
The temperature regulating module has the function of preventing overheating and preventing over cooling.
According to the control object device, select the standard control (heating or cooling) or the heating and cooling control (heating and cooling) mode.
In addition, the mixed control mode (combined with the standard control and heating - cooling control) can be selected.
Peak current suppression.
Can prevent the simultaneous opening of the output to control the peak current, which is helpful for saving energy and reducing the operation cost.
Heating function at the same time.
The multiple loop can reacch the set value at the same time to carry out the uniform temperature control,
Helps to prevent no-load and effective energy saving and reduce operating costs Q00JCPU-E Application Manual Q00JCPU-E User's Manual.
Automatic adjustment function.
The PID constant can be adjusted automatically in the control process Q00JCPU-E Application Manual Q00JCPU-E User's Manual.
Automatic adjustment of cost (time, material and electrical energy) can be reduced.
Related products
MITSUBISHI
CPU with base plate
Q00JCPU
MITSUBISHI CPU with base plate Q00JCPU
Program capacity: 8K step. Input / output poi
MITSUBISHI
CPU with base plate
Q00JCPU-S8
MITSUBISHI CPU with base plate Q00JCPU-S8
DC5V DC current consumption: 0.23A. Numer of
MITSUBISHI
Small points with substrate CPU
Q00JCPU-S8-SET
MITSUBISHI Small points with substrate CPU Q00JCPU-S8-SET
Input / output points: 256 points. Program ca
MITSUBISHI
Small points with substrate CPU
Q00JCPU-SET
MITSUBISHI Small points with substrate CPU Q00JCPU-SET
Input / output points: 256 points. Program ca