MITSUBISHI
Home >> Products >> MITSUBISHI >> Q series PLC >> Other CPU >> Basic type CPU >> Q00JCPU-S8-SET | MITSUBISHI Small points with substrate CPU Q00JCPU-S8-SET

Q00JCPU-S8-SET | MITSUBISHI Small points with substrate CPU Q00JCPU-S8-SET

MITSUBISHI Q00JCPU-S8-SET Manual And Instructions
Q00JCPU-S8-SET datasheetPDF datasheet
Q00JCPU-S8-SET datasheetPDF datasheet
Q00JCPU-S8-SET Special InstructionsStrctured Programming Manual
Q00JCPU-S8-SET Application FunctionsStrctured Programming Manual
Q00JCPU-S8-SET Common InstructionsStrctured Programming Manual
Q00JCPU-S8-SET FundamentalsStrctured Programming Manual
Q00JCPU-S8-SET Multiple CPU SystemUser's Manual
Q00JCPU-S8-SET Function Explanation, Program FundamentalsUser's Manual
Q00JCPU-S8-SET Hardware Design, Maintenance and InspectionUser's Manual
Q00JCPU-S8-SET Structured TextProgramming Manual
Q00JCPU-S8-SET MELSAP-LProgramming Manual
Q00JCPU-S8-SET SFCProgramming Manual
Q00JCPU-S8-SET PID Control InstructionsProgramming Manual
Q00JCPU-S8-SET Common Instructions 1/2Programming Manual
Q00JCPU-S8-SET Structured Text(ST)Programming Guide Book

MITSUBISHI Q00JCPU-S8-SET Product information and technical parameters:
Brand: MITSUBISHI
Name: Small points with substrate CPU
Model: Q00JCPU-S8-SET
Input / output points: 256 points.
Program capacity: 8 K step.
Processing speed: 0.2 s.
Built in communication port: RS232*1.
Continue to go beyond, to climb the peak of Q series.
Strengthen security function.
Can be set up to 32 characters of the file password.
In addition to the English letters, numbers, but also the use of special characters,
To further enhance the security of the password.
In addition, only pre registered devices are allowed to access CPU,
To intercept unauthorized access to unauthorized users.
Therefore, it is important to prevent the outflow of important program assets and protect intellectual property rights.
CPU module expansion standard RAM (max 8MB).
Can be used with the SD memory card at the same time.
Continuous access file register.

4 axis, differential drive output type.
2 axis /4 axis /3 axis linear interpolation.
2 axis interpolation.
Control unit: mm, inch, degree, pulse.
Location data: 600 data / axis.
Maximum pulse output: 1Mpps.
40 pin connector.
Positioning module.
Open collector output.
Differential driver output.
Can also meet the needs of high speed, high precision control MITSUBISHI Q00JCPU-S8-SET.
Most suitable analog modules for high speed conversion control Q00JCPU-S8-SET
Can provide a variety of analog and digital analog conversion module products.
These modules have a variety of functions, in the connection of equipment, to achieve the greatest flexibility.
Can meet the inverter control, such as high-speed conversion needs.
A variety of modules with excellent performance,
Meet the needs of various control from analog to location MITSUBISHI Q00JCPU-S8-SET.
Q series module products include a variety of types of I/O, analog and positioning function module.
Can fully meet the switch, sensor, such as the input and output, temperature, weight, flow and motor, drive control,
As well as the requirements of high-precision control of the positioning of the industry, the control needs of various fields MITSUBISHI Q00JCPU-S8-SET.
Can also be used in combination with the CPU module to achieve appropriate control.
The possibility of expanding control with intelligent function.
Providing a variety of analog modules, is the ideal choice for process control applications.
Based on the use of open collector outputs and differential drive output type 2 types.
Differential driver output type positioning module can transmit high speed instruction pulse (up to 4Mpps) to the servo amplifier reliably,
Transmission distance of up to 10 meters, to achieve high speed and high precision control.
(the command pulse of the open collector positioning module is highest 200kpps.) Used for a common positive input module (3 line type).4 channel.
Input: DCO~20mA DC-10~10V.
Output (resolution): 0~32000; -32000~32000; 0~64000; -64000~64000.
Conversion speed: 10ms/4 channel.
18 point terminal station.
Isolation between channels.
The possibility of expanding control with intelligent function.
At the same time, the channel isolation analog module realizes high isolation voltage,
Further improve the accuracy of the benchmark.
Provide support for process control using a general purpose programmable controller.
Flow meter, pressure meter, other sensors can be directly connected to analog input,
Control valve can also be directly connected to analog output.
Hardware and installation costs have been greatly reduced due to the need for an external isolation amplifier Q00JCPU-S8-SET.
High insulation strength.
Can isolate electrical interference, such as current and noise, etc..
Standard analog input module.
Isolated analog input modulee Q00JCPU-S8-SET.
No external isolation amplifier required.
Without the use of inter channel isolation analog modules.
Using the inter channel isolation analog module.


...More relevant models >>>>